dc.identifier.citation(2013). Influence of Intravenous Contrast Medium on Dose CalculationUsing CT in Treatment Planning for Oesophageal Cancer. Asian Pacific Journal of Cancer Prevention, 14(3), 1609-1614.en_US
dc.identifier.issn1513-7368
dc.identifier.issn2476-762X
dc.identifier.urihttp://journal.waocp.org/article_27500.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/33625
dc.description.abstract<br /><strong>Objective</strong>: To evaluate the effect of intravenous contrast on dose calculation in radiation treatment planningfor oesophageal cancer. <br /><strong>Methods</strong>: A total of 22 intravein-contrasted patients with oesophageal cancer wereincluded. The Hounsfield unit (HU) value of the enhanced blood stream in thoracic great vessels and heart wasoverridden with 45 HU to simulate the non-contrast CT image, and 145 HU, 245 HU, 345 HU, and 445 HU tomodel the different contrast-enhanced scenarios. 1000 HU and -1000 HU were used to evaluate two non-physiologicextreme scenarios. Variation in dose distribution of the different scenarios was calculated to quantify the effectof contrast enhancement. <br /><strong>Results</strong>: In the contrast-enhanced scenarios, the mean variation in dose for planningtarget volume (PTV) was less than 1.0%, and those for the total lung and spinal cord were less than 0.5%. Whenthe HU value of the blood stream exceeded 245 the average variation exceeded 1.0% for the heart V40. In thenon-physiologic extreme scenarios, the dose variationof PTV was less than 1.0%, while the dose calculations ofthe organs at risk were greater than 2.0%. <br /><strong>Conclusions</strong>: The use of contrast agent does not significantly influencedose calculation of PTV, lung and spinal cord. However, it does have influence on dose accuracy for heart.en_US
dc.format.extent536
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherWest Asia Organization for Cancer Prevention (WAOCP)en_US
dc.relation.ispartofAsian Pacific Journal of Cancer Preventionen_US
dc.subjectContrast mediumen_US
dc.subjectoesophageal canceren_US
dc.subjectdose calculationen_US
dc.subjectRadiation therapyen_US
dc.titleInfluence of Intravenous Contrast Medium on Dose CalculationUsing CT in Treatment Planning for Oesophageal Canceren_US
dc.typeTexten_US
dc.citation.volume14
dc.citation.issue3
dc.citation.spage1609
dc.citation.epage1614


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد