| dc.date.accessioned | 1399-07-08T17:59:06Z | fa_IR |
| dc.date.accessioned | 2020-09-29T17:59:07Z | |
| dc.date.available | 1399-07-08T17:59:06Z | fa_IR |
| dc.date.available | 2020-09-29T17:59:07Z | |
| dc.date.issued | 2013-03-01 | en_US |
| dc.date.issued | 1391-12-11 | fa_IR |
| dc.identifier.citation | (2013). Influence of Intravenous Contrast Medium on Dose CalculationUsing CT in Treatment Planning for Oesophageal Cancer. Asian Pacific Journal of Cancer Prevention, 14(3), 1609-1614. | en_US |
| dc.identifier.issn | 1513-7368 | |
| dc.identifier.issn | 2476-762X | |
| dc.identifier.uri | http://journal.waocp.org/article_27500.html | |
| dc.identifier.uri | https://iranjournals.nlai.ir/handle/123456789/33625 | |
| dc.description.abstract | <br /><strong>Objective</strong>: To evaluate the effect of intravenous contrast on dose calculation in radiation treatment planningfor oesophageal cancer. <br /><strong>Methods</strong>: A total of 22 intravein-contrasted patients with oesophageal cancer wereincluded. The Hounsfield unit (HU) value of the enhanced blood stream in thoracic great vessels and heart wasoverridden with 45 HU to simulate the non-contrast CT image, and 145 HU, 245 HU, 345 HU, and 445 HU tomodel the different contrast-enhanced scenarios. 1000 HU and -1000 HU were used to evaluate two non-physiologicextreme scenarios. Variation in dose distribution of the different scenarios was calculated to quantify the effectof contrast enhancement. <br /><strong>Results</strong>: In the contrast-enhanced scenarios, the mean variation in dose for planningtarget volume (PTV) was less than 1.0%, and those for the total lung and spinal cord were less than 0.5%. Whenthe HU value of the blood stream exceeded 245 the average variation exceeded 1.0% for the heart V40. In thenon-physiologic extreme scenarios, the dose variationof PTV was less than 1.0%, while the dose calculations ofthe organs at risk were greater than 2.0%. <br /><strong>Conclusions</strong>: The use of contrast agent does not significantly influencedose calculation of PTV, lung and spinal cord. However, it does have influence on dose accuracy for heart. | en_US |
| dc.format.extent | 536 | |
| dc.format.mimetype | application/pdf | |
| dc.language | English | |
| dc.language.iso | en_US | |
| dc.publisher | West Asia Organization for Cancer Prevention (WAOCP) | en_US |
| dc.relation.ispartof | Asian Pacific Journal of Cancer Prevention | en_US |
| dc.subject | Contrast medium | en_US |
| dc.subject | oesophageal cancer | en_US |
| dc.subject | dose calculation | en_US |
| dc.subject | Radiation therapy | en_US |
| dc.title | Influence of Intravenous Contrast Medium on Dose CalculationUsing CT in Treatment Planning for Oesophageal Cancer | en_US |
| dc.type | Text | en_US |
| dc.citation.volume | 14 | |
| dc.citation.issue | 3 | |
| dc.citation.spage | 1609 | |
| dc.citation.epage | 1614 | |