dc.identifier.citationNyathi, Mpumelelo. (2019). Utilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structures. Iranian Journal of Medical Physics, 16(4), 300-306. doi: 10.22038/ijmp.2018.27777.1297en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.27777.1297
dc.identifier.urihttp://ijmp.mums.ac.ir/article_11784.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324970
dc.description.abstract<strong><em>Introduction:</em></strong>Low-pass filters eliminate noise, and accordingly improve the quality of filtered back-projection (FBP) in the reconstruction of single photon emission computed tomography (SPECT) images. This study aimed at selection of an optimum low-pass filter for FBP reconstruction of SPECT images of small structures. <strong><em>Material and Methods:</em></strong>Spheres A, B, and C (16 mm, 12 mm, and 11 mm in diameter, respectively) attached to capillary stems were filled with technetium-99m solution (activity concentration 300 kBq/mL). They were then mounted inside a Jaszczak Phantom forming a V-shaped structure. The phantom was then filled with distilled water. Two-dimensional (2D) projections were acquired on 128 128 pixels using a Siemens E-Cam dual-head gamma camera. The Parzen, Shepp-Logan, Low Pass Cosine filters (cut-off frequencies: 0.2-0.9), and Butterworth filter (order: 1-9; cut-off frequencies: 0.3-0.9) were employed during FBP reconstruction. The line command of ImageJ software was used to draw the point spread functions of acquired 2D transaxial central slices and for the measurement of their full-width at half-maximum (FWHM). <strong><em>Results:</em></strong>The FWHM of 2D central image slices of spheres A, B, and C reconstructed using a Butterworth filter measured 20, 20, and 10 pixels, respectively. In comparison, the reconstructed images using the Parzen, Low Pass Cosine, and Shepp-Logan filters measured to 27, 25 and, 22 pixels for sphere A, 24, 22, 20 pixels for B, and 22, 20, 18 pixels for C, respectively. <strong><em>Conclusion: </em></strong>The low-pass filters successfully suppressed noise during the FBP reconstruction of SPECT images of small structures. Accordingly, the Butterworth is a suitable choice.en_US
dc.format.extent1045
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.27777.1297
dc.subjectNuclear Medicineen_US
dc.subjectSPECTen_US
dc.subjectImagingen_US
dc.subjectRadionuclide Imagingen_US
dc.subjectMedical Application of Computer Simulationen_US
dc.subjectMedical Physicsen_US
dc.subjectPhysics of Nuclear Medicineen_US
dc.titleUtilization of an optimum low-pass filter during filtered back-projection in the reconstruction of single photon emission computed tomography images of small structuresen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentDepartment of Medical Physics Sefako Makgatho Health Sciences University SouthAfricaen_US
dc.citation.volume16
dc.citation.issue4
dc.citation.spage300
dc.citation.epage306
nlai.contributor.orcid0000-0001-5874-7957


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد