نمایش مختصر رکورد

dc.contributor.authorMahdavi, Mohammaden_US
dc.contributor.authorHosseinnezhad, Masoumeen_US
dc.contributor.authorMahdavi, S.R.M.en_US
dc.date.accessioned1399-07-09T07:35:24Zfa_IR
dc.date.accessioned2020-09-30T07:35:24Z
dc.date.available1399-07-09T07:35:24Zfa_IR
dc.date.available2020-09-30T07:35:24Z
dc.date.issued2018-10-01en_US
dc.date.issued1397-07-09fa_IR
dc.date.submitted2017-10-31en_US
dc.date.submitted1396-08-09fa_IR
dc.identifier.citationMahdavi, Mohammad, Hosseinnezhad, Masoume, Mahdavi, S.R.M.. (2018). Development of an Advanced Optical Coherence Tomography System for Radiation Dosimetry. Iranian Journal of Medical Physics, 15(4), 243-250. doi: 10.22038/ijmp.2018.27121.1279en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.27121.1279
dc.identifier.urihttp://ijmp.mums.ac.ir/article_10468.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324914
dc.description.abstract<strong><em>Introduction:</em></strong> According to the literature, optical coherence tomography (OCT) can be used measure radiation absorbed dose. This study was carried out to design a computed tomography system for the calculation of absorbed dose and optimization of dose delivery in radiotherapy using gel dosimeters.<br /> <strong><em>Material and Methods:</em></strong> An advanced charge-coupled device based OCT system was developed in laboratory with the capability for high resolution three-dimensional (3D) radiation dosimetry using gel dosimeters. The OCT system was compared to magnetic resonance imaging (MRI) as a standard system to investigate its accuracy. Additionally, a number of parameters were checked for assessing the performance of the system.<br /> <strong><em>Results:</em></strong> Developing an advanced OCT system, the calibration curve was drawn for OCT and MRI and the received dose values were compared. The amounts of dose obtained from OCT and MRI were 1.98 and 2 Gy respectively with a relative difference of 2%.<br /> <strong><em>Conclusion: </em></strong>The quality of treatment can be improved using OCT system in radiotherapy dosimetry.en_US
dc.format.extent544
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.27121.1279
dc.subjectCharges Coupled Deviceen_US
dc.subjectOptical Coherenceen_US
dc.subjectTomography Magneticen_US
dc.subjectResonance Imagingen_US
dc.subjectGels Radiometry Doseen_US
dc.subjectComputed Tomography (CT)en_US
dc.subjectMedical Physicsen_US
dc.subjectRadiation Detection & Measurementen_US
dc.titleDevelopment of an Advanced Optical Coherence Tomography System for Radiation Dosimetryen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentMazanderan Universityen_US
dc.contributor.departmentUniversity of Mazandaranen_US
dc.contributor.departmentDepartment of Medical Physics Iran University of Medical Sciences, Tehranen_US
dc.citation.volume15
dc.citation.issue4
dc.citation.spage243
dc.citation.epage250


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد