نمایش مختصر رکورد

dc.contributor.authorAllaveisi, Farzanehen_US
dc.contributor.authorSalehi, Zeinaben_US
dc.contributor.authorAmini, Nasrinen_US
dc.contributor.authorNikzad, Safooraen_US
dc.date.accessioned1399-07-09T07:34:47Zfa_IR
dc.date.accessioned2020-09-30T07:34:47Z
dc.date.available1399-07-09T07:34:47Zfa_IR
dc.date.available2020-09-30T07:34:47Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationAllaveisi, Farzaneh, Salehi, Zeinab, Amini, Nasrin, Nikzad, Safoora. (2018). Comparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic study. Iranian Journal of Medical Physics, 15(12), 443-443. doi: 10.22038/ijmp.2018.13134en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.13134
dc.identifier.urihttp://ijmp.mums.ac.ir/article_13134.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324716
dc.description.abstract<strong>Introduction</strong>: This study aims to compare the dose delivery parameters and radiobiologic model prediction of Tumor Control Probability (TCP) of the FIMRT technique compared with rectangular two tangential wedged fields (2FW) in the treatment of breast cancer. Furthermore, reduction of the heart and lung dose in the FIMRT was studied via dosimetric parameters and radiobiologic model prediction of Normal Tissue Complication Probability (NTCP). <strong>Materials and Methods: </strong>25 left-sided breast cancer patients were selected. The planning target volume (PTV) and organs at risk (heart ad ipsilateral lung) were countered. The tangential technique of treatment planning consists of two optimized wedged beam (2FW) were compared to FIMRT plans for same patients. The FIMRT and 2FW was planned for delivery of 50Gy dose to the target for 25 fractions. The minimum dose, maximum dose, mean dose and homogeneity index (HI) of the dose for the PTV were obtained for both techniques.  Moreover, maximum and mean dose for the lung and heart tissues were obtained. The monitor unit (MUs) and the PTV97% were recorded. Paired samples t-test was used for statistical analysis and p<0.05 was considered as significant level. TCP and NTCP for radiation pneumonitis and late heart mortality was calculated with the Lyman model for organs at risk using dose-volume histogram (DVH). <strong>Results: </strong>the homogeneity index between the two techniques was significant (p>0.05), HI= 1.32 vs 1.10 for 2FW and FIF, respectively. Mean dose to the breast PTV as mean±standard deviation value was 46.6±0.5 Gy for FIMRT vs. 46.8±1.3 Gy for 2FW plans. The PTV97% was 92.5%± 3.2%, and 91.1%± 3.7 for the FIMRT and 2FW. The MUs of the 2FW plans and FIMRT plans were 326.4±11.2 and 212±10.3, respectively. With the FIMRT, the mean dose of the heart and the lung was (2.9Gy vs. 1.9Gy) and (12.1Gy vs. 8.3Gy) respectively; the maximum doses in the heart and lung were decreased significantly from (3.5Gy to 2.1Gy) and (15.8Gy to 10.2Gy) in favor of the FIMRT plans. TCP was 72.3% for FIMRT and 72.1% for 2FW plans. The NTCP for radiation pneumonitis was (0.4%±0.1%) and (0.6%±0.5%) for the FIMRT and 2FW techniques, respectively. The NTCP for late heart was (6.1%±2.1%) for the 2FW technique. However, it was reduced to (3.8%±1.9%) in the FIMRT technique. Differences of the NTCP values were statistically significant for both lung and heart (p<0.05). <strong>Conclusion: </strong>the treatment MUs were significantly reduced by the FIF-RT technique (p<0.05). For all organs, mean NTCP were lower for FIMRT than for the 2FW plans. The FIMRT delivered more homogenous dose to the target while maintaining or increasing the TCP. The FIMRT technique can be considered as a straightforward and fast technique to use clinically particularly in clinics that have not inverse IMRT.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.13134
dc.subjectRadiobiologic modeling FIMRTen_US
dc.subjectBreast cancer Conformal Radiotherapy Dosimetryen_US
dc.subjectHeart dose Lung doseen_US
dc.titleComparison of forward intensity modulated radiation therapy and two field tangential wedged beam techniques in radiotherapy of breast cancer: dosimetric and radiobiologic studyen_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentDepartment of Medical Physics, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran.en_US
dc.contributor.departmentDepartment of Radiation Therapy, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran.en_US
dc.contributor.departmentDepartment of Radiation Therapy, Faculty of Medicine, Kurdistan University of Medical Sciences, Sanandaj, Iran.en_US
dc.contributor.departmentDepartment of Medical Physics, Faculty of Medicine, Hamadan University of Medical Sciences, Hamadan, Iran.en_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage443
dc.citation.epage443
nlai.contributor.orcid0000-0001-5156-4074


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد