نمایش مختصر رکورد

dc.contributor.authorBordbar, Royaen_US
dc.contributor.authorshabestani Monfared, Alien_US
dc.contributor.authorDeevband, Mohammad Rezaen_US
dc.contributor.authorNiksirat, Fatemehen_US
dc.contributor.authorEbrahimnejad Gorji, Kouroshen_US
dc.date.accessioned1399-07-09T07:34:17Zfa_IR
dc.date.accessioned2020-09-30T07:34:17Z
dc.date.available1399-07-09T07:34:17Zfa_IR
dc.date.available2020-09-30T07:34:17Z
dc.date.issued2018-12-01en_US
dc.date.issued1397-09-10fa_IR
dc.date.submitted2018-05-21en_US
dc.date.submitted1397-02-31fa_IR
dc.identifier.citationBordbar, Roya, shabestani Monfared, Ali, Deevband, Mohammad Reza, Niksirat, Fatemeh, Ebrahimnejad Gorji, Kourosh. (2018). Determination of Diagnostic Reference Level in routine Computed radiography examination in north of Iran. Iranian Journal of Medical Physics, 15(12), 267-267. doi: 10.22038/ijmp.2018.12911en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2018.12911
dc.identifier.urihttp://ijmp.mums.ac.ir/article_12911.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324558
dc.description.abstract<strong>Introduction</strong>: Digital radiography has a major role in nowadays healthcare system so radiation protection (justification and optimization) is important in this field. Many related organizations to protection suggested to establish national and regional diagnostic reference level for medical procedures. Reference levels are typically set at the 75th percentile of the dose distribution from a survey conducted across a broad user base using a special dose measurement protocol and phantom. This study aimed to establish diagnostic reference level for computed radiography examination in north of Iran. <strong>Materials and Methods:</strong> The data were collected from 7 public hospitals for 12 computed radiographies routine examination including: skull (AP-LAT), cervical (AP-LAT), chest (PA –LAT), thoracic (AP- LAT), lumbar(AP-LAT), abdomen(AP) and pelvis (AP). For each projection, 10 patients at least 18 years olds were investigated. The study was performed by filling out the questioner which was contained the following parameters: Center name, machine manufacturer, Type of Examination, Tube Voltage (kVp), Current Time Product (mAs) and Film Focus Distance (FFD). The quantity of entrance skin dose is evaluated by measuring ESD. The third quartile of ESD related to each projection was considered as DRL of that examination. <strong>Results:</strong> Based on the data of this study, we expected that diagnostic reference level of computed radiography examination in north of Iran is in accordance with standard values that were suggested by regulatory organizations such as American College of Radiology (ACR)and European Commission (EC). <strong>Conclusion:</strong> The comparison of the results of this survey with surveys performed in other countries will indicate the protection level of patients in computed radiography examination in north of Iran.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2018.12911
dc.subjectComputed radiographyen_US
dc.subjectReference Valuesen_US
dc.subjectDosimetryen_US
dc.subjectPopulation Exposureen_US
dc.titleDetermination of Diagnostic Reference Level in routine Computed radiography examination in north of Iranen_US
dc.typeTexten_US
dc.typeConference Proceedingsen_US
dc.contributor.departmentMsc Student of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iranen_US
dc.contributor.departmentProfessor of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iranen_US
dc.contributor.departmentPHD of Medical Physics, Department of Medical Physics and Engineering, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iranen_US
dc.contributor.departmentMSc of Medical Physics Radiobiology and Radiation Protection Department, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iranen_US
dc.contributor.departmentPHD of Medical Physics, Department of Medical Physics Radiobiology and Radiation Protection, Faculty of Medicine, Babol University of Medical Sciences, Babol, Iranen_US
dc.citation.volume15
dc.citation.issue12
dc.citation.spage267
dc.citation.epage267
nlai.contributor.orcid0000-0002-3082-7346


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد