نمایش مختصر رکورد

dc.contributor.authorAkbarzadeh, Afshinen_US
dc.contributor.authorAy, Mohammad Rrezaen_US
dc.contributor.authorGhadiri, Hosseinen_US
dc.contributor.authorSarkar, Saieden_US
dc.date.accessioned1399-07-09T07:33:11Zfa_IR
dc.date.accessioned2020-09-30T07:33:11Z
dc.date.available1399-07-09T07:33:11Zfa_IR
dc.date.available2020-09-30T07:33:11Z
dc.date.issued2009-06-01en_US
dc.date.issued1388-03-11fa_IR
dc.date.submitted2008-12-15en_US
dc.date.submitted1387-09-25fa_IR
dc.identifier.citationAkbarzadeh, Afshin, Ay, Mohammad Rreza, Ghadiri, Hossein, Sarkar, Saied. (2009). Calculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurement. Iranian Journal of Medical Physics, 6(2), 1-10. doi: 10.22038/ijmp.2009.7290en_US
dc.identifier.issn2345-3672
dc.identifier.urihttps://dx.doi.org/10.22038/ijmp.2009.7290
dc.identifier.urihttp://ijmp.mums.ac.ir/article_7290.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/324204
dc.description.abstract<strong>Introduction: </strong>One of the most important parameters in x-ray CT imaging is the noise induced by detected scattered radiation. The detected scattered radiation is completely dependent on the scanner geometry as well as size, shape and material of the scanned object. The magnitude and spatial distribution of the scattered radiation in x-ray CT should be quantified for development of robust scatter correction techniques. Empirical methods based on blocking the primary photons in a small region are not able to extract scatter in all elements of the detector array while the scatter profile is required for a scatter correction procedure. In this study, we measured scatter profiles in 64 slice CT scanners using a new experimental measurement. <br/><strong>Material and Methods: </strong>To measure the scatter profile, a lead block array was inserted under the collimator and the phantom was exposed at the isocenter. The raw data file, which contained detector array readouts, was transferred to a PC and was read using a dedicated GUI running under MatLab 7.5. The scatter profile was extracted by interpolating the shadowed area. <br/><strong>Results: </strong>The scatter and SPR profiles were measured. Increasing the tube voltage from 80 to 140 kVp resulted in an 80% fall off in SPR for a water phantom (d=210 mm) and 86% for a polypropylene phantom (d = 350 mm). Increasing the air gap to 20.9 cm caused a 30% decrease in SPR. <br/><strong>Conclusion:</strong> In this study, we presented a novel approach for measurement of scattered radiation distribution and SPR in a CT scanner with 64-slice capability using a lead block array. The method can also be used on other multi-slice CT scanners. The proposed technique can accurately estimate scatter profiles. It is relatively straightforward, easy to use, and can be used for any related measurement.en_US
dc.format.extent1173
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Medical Physicsen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/ijmp.2009.7290
dc.subjectScatteren_US
dc.subjectScatter to Primary Ratio (SPR)en_US
dc.subjectComputed Tomography (CT)en_US
dc.subjectMedical Application of Computer Simulationen_US
dc.subjectMedical Physicsen_US
dc.titleCalculation of the Scattered Radiation Profile in 64 Slice CT Scanners Using Experimental Measurementen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentPh.D. Student, Department of Medical Physics and Biomedical Engineering and Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iranen_US
dc.contributor.departmentAssistant Professor in Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences & Research Center for Science and Technology in Medicine, Tehran, Iran.en_US
dc.contributor.departmentPh.D. Student, Department of Medical Physics and Biomedical Engineering and Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iranen_US
dc.contributor.departmentAssociate Professor in Biomedical Engineering, Biomedical Systems & Medical Physics Dept., Tehran University of Medical Sciences & Research Center for Science and Technology in Medicine, Tehran, Iran.en_US
dc.citation.volume6
dc.citation.issue2
dc.citation.spage1
dc.citation.epage10


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد