نمایش مختصر رکورد

dc.contributor.authorAtila, Alptugen_US
dc.contributor.authorYilmaz, Bilalen_US
dc.date.accessioned1399-07-09T06:57:26Zfa_IR
dc.date.accessioned2020-09-30T06:57:26Z
dc.date.available1399-07-09T06:57:26Zfa_IR
dc.date.available2020-09-30T06:57:26Z
dc.date.issued2015-05-01en_US
dc.date.issued1394-02-11fa_IR
dc.date.submitted2013-09-17en_US
dc.date.submitted1392-06-26fa_IR
dc.identifier.citationAtila, Alptug, Yilmaz, Bilal. (2015). Determination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methods. Iranian Journal of Pharmaceutical Research, 14(2), 443-451. doi: 10.22037/ijpr.2015.1649en_US
dc.identifier.issn1735-0328
dc.identifier.issn1726-6890
dc.identifier.urihttps://dx.doi.org/10.22037/ijpr.2015.1649
dc.identifier.urihttp://ijpr.sbmu.ac.ir/article_1649.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/312735
dc.description.abstractIn this study, simple, fast and reliable cyclic voltammetry (CV), linear sweep voltammetry (LSV), square wave voltammetry (SWV) and differential pulse voltammetry (DPV) methods were developed and validated for determination of bosentan in pharmaceutical preparations. The proposed methods were based on electrochemical oxidation of bosentan at platinum electrode in acetonitrile solution containing 0.1 M TBACIO4. The well-defined oxidation peak was observed at 1.21 V. The calibration curves were linear for bosentan at the concentration range of 5-40 µg/mL for LSV and 5-35 µg/mL for SWV and DPV methods, respectively. Intra- and inter-day precision values for bosentan were less than 4.92, and accuracy (relative error) was better than 6.29%. The mean recovery of bosentan was 100.7% for pharmaceutical preparations. No interference was found from two tablet excipients at the selected assay conditions. Developed methods in this study are accurate, precise and can be easily applied to Tracleer and Diamond tablets as pharmaceutical preparation.en_US
dc.format.extent1435
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSchool of Pharmacy, Shahid Beheshti University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Pharmaceutical Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22037/ijpr.2015.1649
dc.subjectBosentanen_US
dc.subjectCyclic voltammetryen_US
dc.subjectLinear sweep voltammetryen_US
dc.subjectSquare wave voltammetryen_US
dc.subjectDifferential pulse voltammetryen_US
dc.subjectDrug quality controlen_US
dc.titleDetermination of Bosentan in Pharmaceutical Preparations by Linear Sweep, Square Wave and Differential Pulse Voltammetry Methodsen_US
dc.typeTexten_US
dc.typeResearch articleen_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Pharmacy, Ataturk University, 25240, Erzurum, Turkeyen_US
dc.contributor.departmentDepartment of Analytical Chemistry, Faculty of Pharmacy, Ataturk University, 25240, Erzurum, Turkeyen_US
dc.citation.volume14
dc.citation.issue2
dc.citation.spage443
dc.citation.epage451


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد