نمایش مختصر رکورد

dc.contributor.authorMahmoudian, Men_US
dc.contributor.authorFalahatpishe, Hen_US
dc.contributor.authorGholamine, Ben_US
dc.contributor.authorTayebiLen_US
dc.date.accessioned1399-07-09T06:57:03Zfa_IR
dc.date.accessioned2020-09-30T06:57:03Z
dc.date.available1399-07-09T06:57:03Zfa_IR
dc.date.available2020-09-30T06:57:03Z
dc.date.issued2009-10-01en_US
dc.date.issued1388-07-09fa_IR
dc.date.submitted2010-11-20en_US
dc.date.submitted1389-08-29fa_IR
dc.identifier.citationMahmoudian, M, Falahatpishe, H, Gholamine, B, TayebiL. (2009). Determination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Study. Iranian Journal of Pharmaceutical Research, 8(4), 251-255. doi: 10.22037/ijpr.2010.818en_US
dc.identifier.issn1735-0328
dc.identifier.issn1726-6890
dc.identifier.urihttps://dx.doi.org/10.22037/ijpr.2010.818
dc.identifier.urihttp://ijpr.sbmu.ac.ir/article_818.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/312613
dc.description.abstractIsosorbide dinitrate (ISDN) is an effective drug in treatment of angina pectoris. In this study a new generation of electron capture detector (non-radioactive) with a short, non-polar and wide-bore column was used for analysis of ISDN in human serum. ISDN was extracted from serum by a mixture of ether and ethyl acetate and concentrated at room temperature. The method was linear between 5-50 ng/mL. Recovery and accuracy were 99-108% and greater than 90%, respectively, and inter-day precision was lower than 13%. Pharmacokinetic parameters were analyzed after oral administrations of Isocor 40 mg sustained release tablet in comparison with Isoket Retard 40. The statistical results obtained from comparison of Cmax, Tmax and AUC ???????????????????????????????????? ?????? ???????????????????????????????????????????????????????????????????????????????? ???????????????????????????????????????????????????????? were reported to be bioequivalent. Further more, the method used was found to be sensitive and accurate in pharmacokinetic studies.en_US
dc.format.extent99
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSchool of Pharmacy, Shahid Beheshti University of Medical Sciencesen_US
dc.relation.ispartofIranian Journal of Pharmaceutical Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22037/ijpr.2010.818
dc.subjectIsosorbide dinitrateen_US
dc.subjectGas chromatographyen_US
dc.subjectElectron capture detectoren_US
dc.subjectpharmacokineticen_US
dc.subjectSerumen_US
dc.titleDetermination of Isosorbide Dinitrate in Serum by Gas Chromatography with New Generation of Electron Capture Detector and its Application in Pharmacokinetic Studyen_US
dc.typeTexten_US
dc.citation.volume8
dc.citation.issue4
dc.citation.spage251
dc.citation.epage255


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد