نمایش مختصر رکورد

dc.contributor.authorRezaei, Hen_US
dc.contributor.authorMostaghimi, Hen_US
dc.contributor.authorMehdizadeh, A Ren_US
dc.date.accessioned1399-07-08T17:40:02Zfa_IR
dc.date.accessioned2020-09-29T17:40:02Z
dc.date.available1399-07-08T17:40:02Zfa_IR
dc.date.available2020-09-29T17:40:02Z
dc.date.issued2017-09-01en_US
dc.date.issued1396-06-10fa_IR
dc.date.submitted2017-05-10en_US
dc.date.submitted1396-02-20fa_IR
dc.identifier.citationRezaei, H, Mostaghimi, H, Mehdizadeh, A R. (2017). Modification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seeds. Journal of Biomedical Physics and Engineering, 7(3), 191-204.en_US
dc.identifier.issn2251-7200
dc.identifier.urihttps://jbpe.sums.ac.ir/article_43265.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/26419
dc.description.abstractBackground: A new treatment approach for most patients who have undergone early stage non-small-cell lung carcinoma (NSCLC) is wedge resection plus permanent implant brachytherapy. However, the specification of dose to medium at low energies especially in heterogeneous lung is unclear yet. <br />Objective: The present study aims to modify source strength for different configurations of 125I and 103Pd seeds used in lung permanent implant brachytherapy.<br />Methods: Different arrays of 125I and 103Pd seeds were simulated by MCNPX code in protocol-based water vs. actual 3D lung environments. Absorbed dose was, then, scored in both mediums. Dose differences between both environments were calculated and source strength was modified for the prescription point. In addition, lung-to-water absorbed dose ratio was obtained and presented by precise equations.<br />Results: Due to significant differences in prescription dose, source strength was modified 16%-19% and 37%-43% for different configurations of 125I and 103Pd seeds, respectively. In addition, depth-dependent dose differences were observed between the actual lung and protocol-based water mediums (dose difference as a function of depth). <br />Conclusion: Modification of source strength is essential for different arrangements of 125I and 103Pd seeds in lung implantation. Modified source strength and presented equations are recommended to be considered in future studies based on lung brachytherapy.en_US
dc.format.extent628
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherShiraz University of Medical Sciencesen_US
dc.relation.ispartofJournal of Biomedical Physics and Engineeringen_US
dc.subject125I seeden_US
dc.subject103Pd seeden_US
dc.subjectlung permanent implant brachytherapyen_US
dc.subjectMonte Carlo Methoden_US
dc.titleModification of Source Strength in Low-Dose-Rate Lung Brachytherapy with 125I and 103Pd seedsen_US
dc.typeTexten_US
dc.typeOriginal Researchen_US
dc.contributor.departmentDepartment of Radiology, School of Paramedical Sciences, Shiraz University of Medical Sciences, Shiraz, Iranen_US
dc.contributor.departmentDepartment of Biomedical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iranen_US
dc.contributor.departmentDepartment of Biomedical Physics and Engineering, School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iranen_US
dc.citation.volume7
dc.citation.issue3
dc.citation.spage191
dc.citation.epage204


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد