نمایش مختصر رکورد

dc.contributor.authorMollahosseini, Afsanehen_US
dc.contributor.authorKonh, Mahsaen_US
dc.date.accessioned1399-07-09T01:17:53Zfa_IR
dc.date.accessioned2020-09-30T01:17:53Z
dc.date.available1399-07-09T01:17:53Zfa_IR
dc.date.available2020-09-30T01:17:53Z
dc.date.issued2019-11-01en_US
dc.date.issued1398-08-10fa_IR
dc.date.submitted2018-12-29en_US
dc.date.submitted1397-10-08fa_IR
dc.identifier.citationMollahosseini, Afsaneh, Konh, Mahsa. (2019). A Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samples. Journal of Sciences, Islamic Republic of Iran, 30(4), 315-323. doi: 10.22059/jsciences.2019.272310.1007352en_US
dc.identifier.issn1016-1104
dc.identifier.issn2345-6914
dc.identifier.urihttps://dx.doi.org/10.22059/jsciences.2019.272310.1007352
dc.identifier.urihttps://jsciences.ut.ac.ir/article_73607.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/196166
dc.description.abstractIn this work, we successfully developed electromembrane extraction via preparation of an electrospun flat membrane based on device. The polyurethane-membrane was prepared by electrospinning method and used in EME. Affecting parameters on membrane preparation were optimized by Taguchi design. The developed method was used for extraction of phthalates as typical molecules and the proposed method was used to determine phthalates in water samples. The applied voltage, extraction time, distance of electrodes and agitation rate were selected as the main factors in EME and optimized using response surface methodology based on a central composite design. Under optimum conditions, calibration curves were obtained in the range of 0.5-5000 ng mL<sup>-1</sup> with R<sup>2</sup>>0.990. The repeatabilities were less than 12% and 14% for intra-day and inter-day, respectively. The limits of detection were found to be 0.03 and 0.02 ng mL<sup>-1</sup> and limits of quantification were obtained 0.09 and 0.06 for bis (2- ethylhexyl phthalate), and dimethyl phthalate, respectively.en_US
dc.format.extent1367
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherUniversity of Tehranen_US
dc.relation.ispartofJournal of Sciences, Islamic Republic of Iranen_US
dc.relation.isversionofhttps://dx.doi.org/10.22059/jsciences.2019.272310.1007352
dc.subjectCentral composite designen_US
dc.subjectEectrospinningen_US
dc.subjectFlat membraneen_US
dc.subjectGas-chromatographyen_US
dc.subjectPhthalatesen_US
dc.subjectchemistryen_US
dc.titleA Developed Electromembrane Technique Based on Flat Electrospun Membrane Coupled with Gas-chromatography for the Determination of Phthalates in Different Water Samplesen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentDepartment of Chemistry, Iran University of Science and Technology, Tehran, Iranen_US
dc.contributor.departmentDepartment of Chemistry and Biochemistry, University of Delaware, Newark, United Statesen_US
dc.citation.volume30
dc.citation.issue4
dc.citation.spage315
dc.citation.epage323


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد