نمایش مختصر رکورد

dc.contributor.authorGhodsi, Javaden_US
dc.contributor.authorRafati, Amir Abbasen_US
dc.contributor.authorShoja, Yaldaen_US
dc.date.accessioned1399-07-08T17:15:25Zfa_IR
dc.date.accessioned2020-09-29T17:15:25Z
dc.date.available1399-07-08T17:15:25Zfa_IR
dc.date.available2020-09-29T17:15:25Z
dc.date.issued2018-09-01en_US
dc.date.issued1397-06-10fa_IR
dc.date.submitted2018-10-02en_US
dc.date.submitted1397-07-10fa_IR
dc.identifier.citationGhodsi, Javad, Rafati, Amir Abbas, Shoja, Yalda. (2018). Determination of acetaminophen using a glassy carbon electrode modified by horseradish peroxidase trapped in MWCNTs/silica sol-gel matrix. Advanced Journal of Chemistry-Section A, 1(1), 39-55. doi: 10.29088/sami/AJCA.2018.5.3955en_US
dc.identifier.issn2645-7768
dc.identifier.issn2645-5676
dc.identifier.urihttps://dx.doi.org/10.29088/sami/AJCA.2018.5.3955
dc.identifier.urihttp://www.ajchem-a.com/article_79902.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/16652
dc.description.abstractA new and easy to fabricate voltammetric biosensor for acetaminophen determination was developed based on horseradish peroxidase (HRP) trapped between silica sol-gel film and multi-walled carbon nanotubes on glassy carbon electrode. Acetaminophen determinations were carried out in presence of H2O2 as enzyme activator. The modified electrode showed excellent electrocatalytic activity and rapid response to acetaminophen in the presence of H2O2 as enzyme activator. Various parameters influencing the biosensor performance such as amount of enzyme, H2O2 concentration, potential scan rate and pH have been investigated. Under the optimal conditions, a wide linear range of 1.85×10−6 to 2.7×10−3 M for acetaminophen determination was obtained. Limit of detection was calculated about 18 nM and sensitivity was about 220 nA/µM. Furthermore, the proposed biosensor was successfully examined for simultaneous determination of acetaminophen with uric acid (UA) and folic acid (FA) as prevalent interferes. The proposed biosensor showed satisfactory stability for 3 weeks and applicability of developed biosensor was confirmed with accurately evaluation of acetaminophen in real samples such as urine and tablet.en_US
dc.format.extent1967
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSami Publishing Company (SPC)en_US
dc.relation.ispartofAdvanced Journal of Chemistry-Section Aen_US
dc.relation.isversionofhttps://dx.doi.org/10.29088/sami/AJCA.2018.5.3955
dc.subjectBiosensoren_US
dc.subjectHorseradish peroxidaseen_US
dc.subjectAcetaminophenen_US
dc.subjectEnzyme Immobilizationen_US
dc.subjectMulti-walled carbon nanotubeen_US
dc.subjectSimultaneous determinationen_US
dc.subjectAnalytical chemistryen_US
dc.titleDetermination of acetaminophen using a glassy carbon electrode modified by horseradish peroxidase trapped in MWCNTs/silica sol-gel matrixen_US
dc.typeTexten_US
dc.typeOriginal Research Articleen_US
dc.contributor.departmentDepartment of Physical Chemistry, Faculty of Chemistry, Bu-Ali Sina University, P.O.Box 65174, Hamedan, Iranen_US
dc.contributor.departmentDepartment of Physical Chemistry, Faculty of Chemistry, Bu-Ali Sina University, P.O.Box 65174, Hamedan, Iranen_US
dc.contributor.departmentDepartment of Physical Chemistry, Faculty of Chemistry, Bu-Ali Sina University, P.O.Box 65174, Hamedan, Iranen_US
dc.citation.volume1
dc.citation.issue1
dc.citation.spage39
dc.citation.epage55


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد