    Evaluation of Polyvinyl Chloride Functionalized with 3-(2-Thiazolylazo)-2,6-diaminopyridineas a New Chelating Resin for On-line Pre-concentration and Determination of Traces of Cadmium in Real Samples by Flame Atomic Absorption Spectrometry

    (ندگان)پدیدآور
    Bagherian, GhadamaliPourbahramian, AminBahramian, BahramArab Chamjangali, MansourAshrafi, Motahare
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    704.3کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In the present work, an on-line solid-phase extraction system is proposed for the preconcentration and accurate determination of trace amounts of cadmium(II) ions by flame atomic absorption spectrometry. The preconcentration of cadmium(II) ions was performed using polyvinyl chloride functionalized with 3-(2-thiazolylazo)-2,6-diaminopyridine in a minicolumn system. The adsorbed cadmium(II) ions were then eluted from the sorbent by the eluent. The important influencing parameters such as the sample solution pH, type and concentration of the eluent used for stripping cadmium(II) ions from the sorbent, flow rate of the sample and the eluent, and amount of adsorbent were investigated in detail. Under the optimum experimental conditions, the linear dynamic range of the method was found to be in the range of 2.0–40.0 µg L−1 (with the determination coefficient equal to 0.9987). The limit of detection and improvement factor were 0.7 µg L−1 and 52.4, respectively. The inter assay precession (RSD%, n=7) was in the range of 0.8-4.1% at the concentration levels of 5.00, 9.00, and 25.0 µg L−1. The validated method was successfully employed for determination of cadmium(II) ions at trace levels in the spiked water and soil samples with satisfactory results.
    کلید واژگان
    Cadmium(II)
    Solid-phase extraction
    Preconcentration
    Flame atomic absorption spectrometry
    3-(2-Thiazolylazo)-2
    6-diamino pyridine
    Polyvinyl chloride

    شماره نشریه
    1
    تاریخ نشر
    2021-01-01
    1399-10-12
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    College of Chemistry, Shahrood University of Technology, Shahrood, P. O. Box: 36155-316, Iran
    College of Chemistry, Shahrood University of Technology, Shahrood, P.O. Box 36155-316, Iran
    College of Chemistry, Shahrood University of Technology, Shahrood, P. O. Box: 36155-316, Iran
    College of Chemistry, Shahrood University of Technology, Shahrood, P. O. Box: 36155-316, Iran
    College of Chemistry, Shahrood University of Technology, Shahrood, P. O. Box: 36155-316, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2020.204689.1409
    http://www.analchemres.org/article_113857.html
    https://iranjournals.nlai.ir/handle/123456789/99467

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب