• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 8, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 8, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development of a Method Based on the Needle-trap Microextraction Filled with Hydroxyapatite and Polyaniline Nanocomposite for Determination of Volatile Organic Compounds in the Air

    (ندگان)پدیدآور
    Bahrami, AbdulrahmanSanaei, NasimGhorbani Shahna, FarshidHabibi Mohraz, MajidFarhadian, Maryam
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    675.8کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this study, the efficiency of packed needle trap with hydroxyapatite/polyaniline (NTD-HAP/PA) nanocomposite was assessed in air sampling and analysis of a hazardous group of VOCs such as benzene, toluene, ethylbenzene and xylenes. The effects of main parameters, including desorption temperature and time, were evaluated on the performance and carryover of prepared NTDs. Moreover, the repeatability, reproducibility and stability of the developed sampler were investigated for the sampling and determination of the interest analytes. The results of experiments indicated that the highest peak area was obtained at desorption temperature and time of 250˚C and 3 min, respectively. The reproducibility of the proposed method was investigated with three distinct NTDs with similar structure. The weight of the adsorbent also was obtained results showed that the relative standard deviation (RSD) of experiments was in the range of 0.2-9.7%. The RSD of repeatability was obtained at four different concentrations, with three times replications less than 15%. The Limit of Detection and Quantitation (LOD and LOQ) for the studied VOCs ranged from 0.01 to 0.14 ng/mL and 0.04 to 0.48 ng / mL, respectively. Also, the storage stability of the analytes of interest in the NTD-HAP/PA after 3 and 7 days at 4 °C was above 95 and 93%, respectively. It can be concluded that the proposed method could be applied as a desirable and powerful tool for air sampling and microextraction of volatile organic compounds
    کلید واژگان
    Needle trap device
    Volatile organic compounds
    Air
    Hydroxyapatite
    Hydroxyapatite/polyaniline nanocomposit

    شماره نشریه
    1
    تاریخ نشر
    2021-01-01
    1399-10-12
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Hamadan university of medical science
    Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
    Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
    Center of Excellence for Occupational Health, Occupational Health and Safety Research Center, School of Public Health, Hamadan University of Medical Sciences, Hamadan, Iran
    Department of Biostatistics, School of Public Health and Research Center for Health Sciences, Hamadan Uni versity of Medical Sciences, Ðamadan, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2020.225018.1477
    http://www.analchemres.org/article_113202.html
    https://iranjournals.nlai.ir/handle/123456789/99464

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب