نمایش مختصر رکورد

dc.contributor.authorAsadi, Mohammaden_US
dc.contributor.authorDadfarnia, Shayesstehen_US
dc.contributor.authorHaji Shabani, Ali Mohammaden_US
dc.date.accessioned1399-07-08T20:56:27Zfa_IR
dc.date.accessioned2020-09-29T20:56:27Z
dc.date.available1399-07-08T20:56:27Zfa_IR
dc.date.available2020-09-29T20:56:27Z
dc.date.issued2017-12-01en_US
dc.date.issued1396-09-10fa_IR
dc.date.submitted2017-04-29en_US
dc.date.submitted1396-02-09fa_IR
dc.identifier.citationAsadi, Mohammad, Dadfarnia, Shayessteh, Haji Shabani, Ali Mohammad. (2017). Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop. Analytical and Bioanalytical Chemistry Research, 4(2), 329-339. doi: 10.22036/abcr.2017.83532.1145en_US
dc.identifier.issn2383-093X
dc.identifier.urihttps://dx.doi.org/10.22036/abcr.2017.83532.1145
dc.identifier.urihttp://www.analchemres.org/article_49073.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/99406
dc.description.abstractThe application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such as the concentration of dithizone as the chelating agent, sample pH, type and volume of the extractant, number of injections, ionic strength and sample volume were optimized. Under optimized conditions, the calibration curve was linear in the range of 1.0-14.0 ng L-1 with the coefficient of determination of 0.9994. The limit of detection and quantification were found to be 0.25 and 0.85 ng L-1, respectively. The inter-day and intra-day precision at two concentration levels (3.0 and 10.0 ng L-1) were in the range of 3.9-9.2%. The accuracy of the developed method was evaluated through recovery experiments and the analysis of certified reference material (SLRS-6).en_US
dc.format.extent819
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIranian Chemical Societyen_US
dc.relation.ispartofAnalytical and Bioanalytical Chemistry Researchen_US
dc.relation.isversionofhttps://dx.doi.org/10.22036/abcr.2017.83532.1145
dc.subjectCadmiumen_US
dc.subjectSyringe to syringe dispersive liquid phase microextractionen_US
dc.subjectSolidified floating organic dropen_US
dc.subjectElectrothermal atomic absorption spectrometryen_US
dc.titleDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Dropen_US
dc.typeTexten_US
dc.typeResearch Paperen_US
dc.contributor.departmentDepartment of Chemistry, Yazd University, Yazd, Iranen_US
dc.contributor.departmentDepartment of Chemistry, Yazd University, Yazd, Iranen_US
dc.contributor.departmentDepartment of Chemistry, Yazd University, Yazd, Iranen_US
dc.citation.volume4
dc.citation.issue2
dc.citation.spage329
dc.citation.epage339
nlai.contributor.orcid0000-0002-1494-8949


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد