• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 4, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Chemistry Research
    • Volume 4, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

    (ندگان)پدیدآور
    Asadi, MohammadDadfarnia, ShayesstehHaji Shabani, Ali Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    820.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such as the concentration of dithizone as the chelating agent, sample pH, type and volume of the extractant, number of injections, ionic strength and sample volume were optimized. Under optimized conditions, the calibration curve was linear in the range of 1.0-14.0 ng L-1 with the coefficient of determination of 0.9994. The limit of detection and quantification were found to be 0.25 and 0.85 ng L-1, respectively. The inter-day and intra-day precision at two concentration levels (3.0 and 10.0 ng L-1) were in the range of 3.9-9.2%. The accuracy of the developed method was evaluated through recovery experiments and the analysis of certified reference material (SLRS-6).
    کلید واژگان
    Cadmium
    Syringe to syringe dispersive liquid phase microextraction
    Solidified floating organic drop
    Electrothermal atomic absorption spectrometry

    شماره نشریه
    2
    تاریخ نشر
    2017-12-01
    1396-09-10
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Yazd University, Yazd, Iran
    Department of Chemistry, Yazd University, Yazd, Iran
    Department of Chemistry, Yazd University, Yazd, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2017.83532.1145
    http://www.analchemres.org/article_49073.html
    https://iranjournals.nlai.ir/handle/123456789/99406

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب