    Synergistic Signal Amplification Based on Ionic Liquid-BaTiO3 Nanoparticle Carbon Paste Electrode for Sensitive Voltammetric Determination of Acetaminophen

    (ندگان)پدیدآور
    Pourtaheri, EhsanTaher, Mohammad AliBeitollahi, Hadi
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    762.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Monitoring the acetaminophen in biological samples and also in pharmaceutical formulations is important due to the concerns of public health care and drug safety. In this work a carbon paste electrode modified with BaTiO3 nanoparticle (BTO NPs) and room-temperature ionic liquid (IL) (n-hexyl-3-methylimidazolium hexafluoro phosphate) was fabricated. The direct electro-oxidation behavior of acetaminophen (AC) was carefully studied by cyclic voltammetry (CV), differential pulse voltammetry (DPV) and chronoamperometry (CHA) and the diffusion coefficient, D of acetaminophen at the BTOILCPE surface was estimated. The results exhibited remarkable increase in the electron transfer rate and significant decrease in the overpotential for acetaminophen oxidation reaction in contrast to that on the bare carbon paste electrode (CPE). Under the optimal conditions, using DPV the oxidation peak current was linear to the acetaminophen concentration over the range of 1.0 to 600.0 μM with a detection limit of 0.46 μM. The proposed sensor was successfully applied in pharmaceutical and urine samples with satisfactory results.
    کلید واژگان
    Acetaminophen
    BaTiO3 nanoparticles
    Ionic Liquid
    Carbon paste electrode
    Voltammetry

    شماره نشریه
    2
    تاریخ نشر
    2018-12-01
    1397-09-10
    ناشر
    Iranian Chemical Society
    سازمان پدید آورنده
    Department of Chemistry, Shahid Bahonar University of Kerman, P.O. Box 76175-133, Kerman, Iran
    Department of Chemistry, Shahid Bahonar University of Kerman, P. O. Box: 76175-133,Kerman, Iran
    Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran

    شاپا
    2383-093X
    URI
    https://dx.doi.org/10.22036/abcr.2018.99508.1166
    http://www.analchemres.org/article_61771.html
    https://iranjournals.nlai.ir/handle/123456789/99383

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب