• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Bulletin of Emergency And Trauma
    • Volume 8, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Bulletin of Emergency And Trauma
    • Volume 8, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Osteoporotic Vertebral Compression Fracture and Single Balloon Extrapedicular Kyphoplasty: Findings and Technical Considerations

    (ندگان)پدیدآور
    Mishra, Pankaj KumarDwivedi, RishiDhillon, Charanjit Singh
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.702 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: To evaluate the functional and radiological outcome of balloon kyphoplasty and to endorse the unilateral single balloon extrapedicular kyphoplasty as practically more feasible and safer method in comparison to the conventional methods.Methods: Totally, 81 patients were presented to our center with osteoporotic vertebral compression fracture. Among these, 59 patients (61 vertebrae) were enrolled with stable wedge osteoporotic compression fracture. Pre-operatively percentage of vertebral height loss and kyphotic angle were calculated and single balloon extrapedicular kyphoplasty was performed in all cases.Results: Postoperatively, anterior vertebral height improved to 79.61% of normal subjects. In our study, the mean segmental kyphosis correction following balloon kyphoplasty was 14.27°. Overall incidence of cement leak in our study was 15.25%.Conclusion: Although we encountered the few difficulties, but this technique holds the safety and feasibility measures. Furthermore, it is effective in restoring anterior vertebral height, alignment and angle of kyphosis.
    کلید واژگان
    Uni-extrapedicular
    Balloon kyphoplasty
    Percutaneous
    Compression fracture

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Department of Orthopaedics, Gandhi Medical College and Hamidia Hospital Bhopal M.P INDIA
    Consultant spine surgeon
    Director of Spine center MIOT international Chennai INDIA

    شاپا
    2322-2522
    2322-3960
    URI
    https://dx.doi.org/10.29252/beat-080106
    https://beat.sums.ac.ir/article_46350.html
    https://iranjournals.nlai.ir/handle/123456789/96985

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب