    Cost and performance analysis of an integrated solar combined cycle with two tanks for indirect thermal energy storage

    (ندگان)پدیدآور
    Shahbazi, BagherTalati, FaramarzSeyyedmahmoodi, MohammadYari, Mortaza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.554 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this paper, the annual and economic performance of an integrated solar combined cycle (ISCC) with indirect energy storage tanks is investigated. The study includes four scenarios, in which the combined cycle performance was studied exclusively in the first scenario. In the second scenario, the integrated solar combined cycle (ISCC) was examined, and the use of supplementary firing instead of solar energy with the assumption of producing the same power as that by the ISCC scenario was examined for the third scenario. For the fourth scenario, the use of energy storage in the form of indirect tanks with the purpose of energy storage during peak solar direct normal irradiation times and discharge during peak power electricity consumption within the network for such power plants were subjected to investigation. Results show that the contribution of solar energy in the annual produced power by the ISCC scenario is 40 GWh, which is 2.2% of the total. In the case that this amount of power is produced using supplementary firing, there will be about 1.98 tons of increased fuel consumption, and about 18 kton increased in CO2 production. By using the energy storage system, the annual power generation increases by 5 GWh, which will raise the plant's annual revenue by 0.25 M$ if the increment occurs during peak hours.  Moreover, the levelized costs of energy (LCOE) for the four scenarios are 8.99, 8.86, 9.04, and 9.135 cents/kWh, respectively.
    کلید واژگان
    Integrated Solar Combined Cycle
    Thermal Energy Storage
    Economic Analysis
    Levelized Cost of Electricity

    شماره نشریه
    3
    تاریخ نشر
    2020-09-01
    1399-06-11
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
    Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
    Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran
    Faculty of Mechanical Engineering, University of Tabriz, Tabriz, Iran

    شاپا
    2383-1111
    2345-251X
    URI
    https://dx.doi.org/10.22059/ees.2020.44642
    http://www.energyequipsys.com/article_44642.html
    https://iranjournals.nlai.ir/handle/123456789/95223

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب