• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Biotechnology
    • Volume 18, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Biotechnology
    • Volume 18, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Multiscale Simulation of Adsorption Based Microcantilever Biosensors for Radiation Exposure Effects

    (ندگان)پدیدآور
    Mollaei, FouadAliparast, PeimanNaghash, Abolghasem
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.268 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: This article is focused on biological measurements based on molecular interactions. The specific biomarker implemented for radiation biosensor is FLT3, which bears changes in the body regarding radiation exposure. Experimental results of sensing vancomycin verify the overall results of two steps of numerical methods for different scales.Objectives: The aim is to provide adequate modeling procedures to predict sensory data. Multiscale modeling is implemented to simulate molecular interaction and its consequent micro mechanical effects. The method is implemented to calculate surface traction of microcantilever biosensor.Materials and Methods: The method consists of molecular dynamics simulation of adsorption process by implementing classical mechanics theory to calculate the final response of the sensor as tip deflection. The sequential information transaction is assumed between the physical parameters of two governing scales. The numerical method consists of the location of particles providing for a nano-metric periodic boundary conditioned functionalized surface implemented, and the numerical thermodynamic formula is, in turn, use energy parameters to acquire macro-mechanical deflection of a specific microcantilever. Also, novel sensitivity analysis of the results as the adsorption process moves toward more saturated substrate provided.Results: Verification of the simulation method for Vancomycin sensing results enjoys less than 20 percent of deviation regarding the experimental data. The standard deviation of 0.054 in the final expected response of the sensor is calculated as the accuracy of the radiation biosensor based on FLT3.Conclusions: The method is still to reach a correlation between the concentration of target molecules in solution and the number of adsorbed molecules per area of the sensor. A scaled correlation between sensor's response and the amount of biomarker is found using tip deflection of a sample designed microcantilever. Around one micrometer deflection that can be read out using various conventional methods was observed at saturation of adsorption surface. The analyses provide adequate data to design a sensor capable of measuring the effect of cosmic radiation to the human body.
    کلید واژگان
    Adsorption
    Micro-Cantilever
    Molecular Dynamics
    Multi-scale
    Molecular Biotechnology

    شماره نشریه
    2
    تاریخ نشر
    2020-06-01
    1399-03-12
    ناشر
    National Institute of Genetic Engineering and Biotechnology
    سازمان پدید آورنده
    Aerospace Research Institute, Ministry of Science and Research and Technology, Tehran, Iran
    Aerospace Research Institute, Ministry of Science and Research and Technology, Tehran, Iran
    Aerospace Engineering Department, Amirkabir University of Technology, Tehran, Iran

    شاپا
    1728-3043
    2322-2921
    URI
    https://dx.doi.org/10.30498/ijb.2020.134636.2317
    http://www.ijbiotech.com/article_114424.html
    https://iranjournals.nlai.ir/handle/123456789/85911

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب