نمایش مختصر رکورد

dc.contributor.authorHosseinalizadeh Khorasani, Jafaren_US
dc.contributor.authorAmini, Mohammad Kazemen_US
dc.contributor.authorGhanei, Hamidehen_US
dc.contributor.authorTangestaninejad, Shahramen_US
dc.date.accessioned1399-07-08T20:17:01Zfa_IR
dc.date.accessioned2020-09-29T20:17:01Z
dc.date.available1399-07-08T20:17:01Zfa_IR
dc.date.available2020-09-29T20:17:01Z
dc.date.issued2001-12-01en_US
dc.date.issued1380-09-10fa_IR
dc.date.submitted2000-10-11en_US
dc.date.submitted1379-07-20fa_IR
dc.identifier.citationHosseinalizadeh Khorasani, Jafar, Amini, Mohammad Kazem, Ghanei, Hamideh, Tangestaninejad, Shahram. (2001). Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine. Iranian Journal of Chemistry and Chemical Engineering (IJCCE), 20(2), 67-74.en_US
dc.identifier.issn1021-9986
dc.identifier.urihttp://www.ijcce.ac.ir/article_9972.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/85032
dc.description.abstract<em>A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detection was 0.013 mM (50 </em><em>m</em><em>L injected), and the calibration plot was linear in the ranges of 0.025-1.0 mM (correlation coefficient, r=0.9989, n=6) and 1.0-10 mM (r=0.9997, n=5). The relative standard deviation for the measurement of ascorbic acid at several concentrations was </em><em>£</em><em>1%. The modified electrode was found to retain its full response in flowing streams for several days of operating time. The results of ascorbic acid quantification in fruit juices and vitamin tables are reported. </em>en_US
dc.format.extent169
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRen_US
dc.relation.ispartofIranian Journal of Chemistry and Chemical Engineering (IJCCE)en_US
dc.subjectAscorbic aciden_US
dc.subjectCobalt phthalocyanineen_US
dc.subjectModified electrodesen_US
dc.subjectAmperometryen_US
dc.subjectFlow-injection analysisen_US
dc.subjectApplied Chemistryen_US
dc.titleFlow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanineen_US
dc.typeTexten_US
dc.typeResearch Articleen_US
dc.contributor.departmentChemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRANen_US
dc.contributor.departmentChemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRANen_US
dc.contributor.departmentChemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRANen_US
dc.contributor.departmentChemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRANen_US
dc.citation.volume20
dc.citation.issue2
dc.citation.spage67
dc.citation.epage74


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد