| dc.contributor.author | Hosseinalizadeh Khorasani, Jafar | en_US |
| dc.contributor.author | Amini, Mohammad Kazem | en_US |
| dc.contributor.author | Ghanei, Hamideh | en_US |
| dc.contributor.author | Tangestaninejad, Shahram | en_US |
| dc.date.accessioned | 1399-07-08T20:17:01Z | fa_IR |
| dc.date.accessioned | 2020-09-29T20:17:01Z | |
| dc.date.available | 1399-07-08T20:17:01Z | fa_IR |
| dc.date.available | 2020-09-29T20:17:01Z | |
| dc.date.issued | 2001-12-01 | en_US |
| dc.date.issued | 1380-09-10 | fa_IR |
| dc.date.submitted | 2000-10-11 | en_US |
| dc.date.submitted | 1379-07-20 | fa_IR |
| dc.identifier.citation | Hosseinalizadeh Khorasani, Jafar, Amini, Mohammad Kazem, Ghanei, Hamideh, Tangestaninejad, Shahram. (2001). Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine. Iranian Journal of Chemistry and Chemical Engineering (IJCCE), 20(2), 67-74. | en_US |
| dc.identifier.issn | 1021-9986 | |
| dc.identifier.uri | http://www.ijcce.ac.ir/article_9972.html | |
| dc.identifier.uri | https://iranjournals.nlai.ir/handle/123456789/85032 | |
| dc.description.abstract | <em>A flow injection method is reported for the determination of ascorbic acid based on amperometric detection, using a cobalt(II) phthalocyanine (CoPc) modified graphite-epoxy electrode. The amperometric respons was evaluated with regard to pH, ionic strength of the electrolyte, flow rate of the carrier solution, injected sample volume and conditioning time of the electrode. The limit of detection was 0.013 mM (50 </em><em>m</em><em>L injected), and the calibration plot was linear in the ranges of 0.025-1.0 mM (correlation coefficient, r=0.9989, n=6) and 1.0-10 mM (r=0.9997, n=5). The relative standard deviation for the measurement of ascorbic acid at several concentrations was </em><em>£</em><em>1%. The modified electrode was found to retain its full response in flowing streams for several days of operating time. The results of ascorbic acid quantification in fruit juices and vitamin tables are reported. </em> | en_US |
| dc.format.extent | 169 | |
| dc.format.mimetype | application/pdf | |
| dc.language | English | |
| dc.language.iso | en_US | |
| dc.publisher | Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR | en_US |
| dc.relation.ispartof | Iranian Journal of Chemistry and Chemical Engineering (IJCCE) | en_US |
| dc.subject | Ascorbic acid | en_US |
| dc.subject | Cobalt phthalocyanine | en_US |
| dc.subject | Modified electrodes | en_US |
| dc.subject | Amperometry | en_US |
| dc.subject | Flow-injection analysis | en_US |
| dc.subject | Applied Chemistry | en_US |
| dc.title | Flow-Injection Amperometric Determination of Ascorbic Acid Using a Graphite-Epoxy Composite Electrode Modified with Cobalt Phthalocyanine | en_US |
| dc.type | Text | en_US |
| dc.type | Research Article | en_US |
| dc.contributor.department | Chemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRAN | en_US |
| dc.contributor.department | Chemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRAN | en_US |
| dc.contributor.department | Chemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRAN | en_US |
| dc.contributor.department | Chemistry Department, University of Isfahan, Isfahan, 81744, I.R. IRAN | en_US |
| dc.citation.volume | 20 | |
| dc.citation.issue | 2 | |
| dc.citation.spage | 67 | |
| dc.citation.epage | 74 | |