    Thermal Design Considerations and Performance Evaluation of Cryogenic Tube in Tube Heat Exchangers

    (ندگان)پدیدآور
    Saberimoghaddam, AliBahri Rasht Abadi, Mohammad Mahdi
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    563.0کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Heat exchangers are the most important equipment in refrigeration processes. Design and modeling of heat exchangers operating at low temperatures are different from other regular heat exchangers. This study includes two sections. In the first section, design and modeling considerations needed for evaluating the real thermal behavior of heat exchangers at low temperatures were discussed. These considerations are usually neglected by researchers who have modeled the heat exchanger at low temperatures.  In the second section, a counter current helically coiled tube in tube heat exchanger operating in hydrogen liquefier was modeled and simulated considering notes discussed in the first section. The model was validated compared with the data presented by literature. The results showed the small positive effect of longitudinal heat conduction on hydrogen liquefaction. The heat in-leak into cold fluid resulted in higher cold fluid outlet temperature and higher hot fluid outlet temperature. Simulations showed that the heat in-leak into cold fluid leads to limit the overdesign for cryogenic heat exchangers. A comparison between models with considering different assumptions was presented and showed that the result may vary significantly based on the regarded assumptions.
    کلید واژگان
    heat exchanger
    longitudinal heat conduction
    heat in-leak
    Low temperature'
    refrigeration
    Energy, Heat Transfer
    Fluid Mechanics, CFD

    شماره نشریه
    1
    تاریخ نشر
    2019-02-01
    1397-11-12
    ناشر
    Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
    سازمان پدید آورنده
    Department of Chemistry and Chemical Engineering, Faculty of Chemical Engineering, Malek Ashtar University of Technology (MUT), Tehran, I.R. IRAN
    Department of Chemistry and Chemical Engineering, Faculty of Chemical Engineering, Malek Ashtar University of Technology (MUT), Tehran, I.R. IRAN

    شاپا
    1021-9986
    URI
    http://www.ijcce.ac.ir/article_29774.html
    https://iranjournals.nlai.ir/handle/123456789/84723

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب