    Fabrication of a Sulfite Biosensor by the Use of Conducting Polymer

    (ندگان)پدیدآور
    Hosseini, MohammadBahmani, BaharakMoztarzadeh, FatollahRabiee, Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    183.8کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In this research, an enzyme modified electrode has been produced during the electropolymerization of aniline through incorporation of sulfite oxidase into a conducting polymer. Then the bioelectrochemical response of resulted sulfite biosensor was investigated at different experimental conditions. Study of  the stability of the resulted sulfite biosensor revealed that formation of a passive film on the aluminum surface causes improved stability of the electroactive films formed on the electrode surface. The bioelectrochemical response of the enzyme-modified electrode as a sulfite biosensor was investigated at different experimental conditions. The optimum pH and temperature were 8.5 and 35°C, respectively. The apparent Michaelis-Menten constant and the activation energy of the enzyme catalyzed reaction were calculated.
    کلید واژگان
    Sulfite biosensor
    Aniline
    Sulfite oxidase
    Conducting polymer
    Biotechnology
    Polymers & Composites

    شماره نشریه
    1
    تاریخ نشر
    2008-03-01
    1386-12-11
    ناشر
    Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
    سازمان پدید آورنده
    Department of Chemical Engineering, Amirkabir University of Technology, P.O. Box 15874-4413 Tehran, I.R. IRAN
    Department of Biomedical Engineering, Amirkabir University of Technology, P.O. Box 15875-4413 Tehran, I.R. IRAN
    Department of Biomedical Engineering, Amirkabir University of Technology, P.O. Box 15875-4413 Tehran, I.R. IRAN
    Department of Biomedical Engineering, Amirkabir University of Technology, P.O. Box 15875-4413 Tehran, I.R. IRAN

    شاپا
    1021-9986
    URI
    http://www.ijcce.ac.ir/article_7132.html
    https://iranjournals.nlai.ir/handle/123456789/84034

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب