• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
    • Volume 28, Issue 4
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Chemistry and Chemical Engineering (IJCCE)
    • Volume 28, Issue 4
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    On-Line Measurement of Dissolved Methane Concentration During Methane Fermentation in a Loop Bioreactor

    (ندگان)پدیدآور
    Yazdian, FatemehShojaosadati, Seyed AbbasNosrati, MohsenPesaran Hajiabbas, MahdiMalek Khosravi, Khosro
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    208.8کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    A dissolved methane sensor based on silicone tube was designed, constructed and optimized.The silicone tube diameter, silicone tube length and helium flow rate (as the carrier gas(were considered as process parameters to be optimized.A continuous stream of helium (50 mL/min) was directed through the tubing, sweeping out the dissolved methane which diffused through the walls of the tubing from the fermentation broth. The probe was made of silicone rubber tubing, 10 cm in length with inner and outer diameters of 0.25 cm and 0.35 cm, respectively (Detakta Company; NO. 02502). A semi-conductor methane gas sensor (Figaro TGS 2611) - which is highly sensitive and selective to methane gas - was used to measure the dissolved methane continuously. Henry's law along with a special circuit experimental method was applied for calibration. The output concentration was displayed in mg/l (or ppm) of dissolved gas. The accuracy and response time of this system are ± 2 % and 2 minutes, respectively. Moreover, a control system was installed for recycling methane gas during fermentation
    کلید واژگان
    Dissolved methane
    Semi-conductor sensor
    On-line measurement
    Loop bioreactor
    Calibration
    Biotechnology

    شماره نشریه
    4
    تاریخ نشر
    2009-12-01
    1388-09-10
    ناشر
    Iranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECR
    سازمان پدید آورنده
    Biotechnology Group, Department of Chemical Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box 14115-143 Tehran, I.R. IRAN
    Biotechnology Group, Department of Chemical Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box 14115-143 Tehran, I.R. IRAN
    Biotechnology Group, Department of Chemical Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box 14115-143 Tehran, I.R. IRAN
    Biotechnology Group, Department of Chemical Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box 14115-143 Tehran, I.R. IRAN
    Biotechnology Group, Department of Chemical Engineering, Faculty of Engineering, Tarbiat Modares University, P.O. Box 14115-143 Tehran, I.R. IRAN

    شاپا
    1021-9986
    URI
    http://www.ijcce.ac.ir/article_6832.html
    https://iranjournals.nlai.ir/handle/123456789/83921

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب