نمایش مختصر رکورد

dc.contributor.authorMazloum-Ardakani, Mohammaden_US
dc.contributor.authorMazidi, Royaen_US
dc.contributor.authorMashhadizadeh, Mohammad Hosseinen_US
dc.contributor.authorNaeimi, Hosseinen_US
dc.contributor.authorRabiei, Kobraen_US
dc.date.accessioned1399-07-08T20:13:38Zfa_IR
dc.date.accessioned2020-09-29T20:13:38Z
dc.date.available1399-07-08T20:13:38Zfa_IR
dc.date.available2020-09-29T20:13:38Z
dc.date.issued2010-09-01en_US
dc.date.issued1389-06-10fa_IR
dc.date.submitted2009-05-11en_US
dc.date.submitted1388-02-21fa_IR
dc.identifier.citationMazloum-Ardakani, Mohammad, Mazidi, Roya, Mashhadizadeh, Mohammad Hossein, Naeimi, Hossein, Rabiei, Kobra. (2010). Highly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complex. Iranian Journal of Chemistry and Chemical Engineering (IJCCE), 29(3), 123-132.en_US
dc.identifier.issn1021-9986
dc.identifier.urihttp://www.ijcce.ac.ir/article_6647.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/83878
dc.description.abstract<em>In this work we introduce a practical use of synthesized Schiff base metal complex in sensing application. A new perchlorate-selective electrode based on the complex N, N'-4-nitro-phenylmethanebis-(salicylaldiminato) copper (II) [CuL] as the membrane carrier was developed. The electrode exhibits a good  Nernstian slope of -55.0 ± 1.0 mV/decade and a linear range of  for perchlorate. The limit of detection is . It has a fast response time </em><em><</em><em>15s and can be used for more than three months. The selective coefficients of Perchlorate-selective</em><em> electrode were determined by the Fixed Interference Method (FIM) and Fixed Primary ion Method (FPM), and could be used in the pH range 4.0-9.0. It was employed as an indicator electrode for direct determination of perchlorate in real samples.</em>en_US
dc.format.extent150
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIranian Institute of Research and Development in Chemical Industries (IRDCI)-ACECRen_US
dc.relation.ispartofIranian Journal of Chemistry and Chemical Engineering (IJCCE)en_US
dc.subjectSchiff Baseen_US
dc.subjectPerchlorate-selective electrodeen_US
dc.subjectPotentiometryen_US
dc.subjectApplied Chemistryen_US
dc.subjectInorganic Chemistryen_US
dc.titleHighly Selective Perchlorate Membrane Electrode Based on Synthesized Schiff Base Complexen_US
dc.typeTexten_US
dc.typeResearch Noteen_US
dc.contributor.departmentDepartment of Chemistry, Faculty of Science, Yazd University, P.O. Box 89195-74 Yazd, I.R. IRANen_US
dc.contributor.departmentDepartment of Chemistry, Payam Noor University, Ardakan Branch, Ardakan, I.R. IRANen_US
dc.contributor.departmentDepartment of Chemistry, Tarbiat Moalem University, Tehran, I.R. IRANen_US
dc.contributor.departmentFaculty of Chemistry, University of Kashan, Kashan, I.R. IRANen_US
dc.contributor.departmentFaculty of Chemistry, University of Kashan, Kashan, I.R. IRANen_US
dc.citation.volume29
dc.citation.issue3
dc.citation.spage123
dc.citation.epage132


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد