نمایش مختصر رکورد

dc.contributor.authorRamezani Azghandi, O.en_US
dc.contributor.authorFarahbakhsh, A.en_US
dc.date.accessioned1399-07-08T20:04:20Zfa_IR
dc.date.accessioned2020-09-29T20:04:20Z
dc.date.available1399-07-08T20:04:20Zfa_IR
dc.date.available2020-09-29T20:04:20Z
dc.date.issued2015-01-01en_US
dc.date.issued1393-10-11fa_IR
dc.date.submitted2013-08-01en_US
dc.date.submitted1392-05-10fa_IR
dc.identifier.citationRamezani Azghandi, O., Farahbakhsh, A.. (2015). The obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4. International Journal of Nano Dimension, 6(1), 23-30. doi: 10.7508/ijnd.2015.06.004en_US
dc.identifier.issn2008-8868
dc.identifier.issn2228-5059
dc.identifier.urihttps://dx.doi.org/10.7508/ijnd.2015.06.004
dc.identifier.urihttp://www.ijnd.ir/article_634357.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/80557
dc.description.abstractThe Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate-buffered saline (PBS) that design software QUALTEK-4 has been tested. The experiments performed tests of the software, with increasing concentration, the current output is increased. Optimal conditions were optioned in neutral pH and maximum glucose concentrations. After confirmation tests in optimum conditions the expected error rate of application lower than 10 %. It shows the true error rate test with high sensitivity and accuracy.en_US
dc.format.extent479
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIslamic Azad University-Tonekabon Branchen_US
dc.relation.ispartofInternational Journal of Nano Dimensionen_US
dc.relation.isversionofhttps://dx.doi.org/10.7508/ijnd.2015.06.004
dc.subjectSensorsen_US
dc.subjectSoftware QUALTEK-4en_US
dc.subjectBiosensorsen_US
dc.subjectcurrenten_US
dc.subjectGlucose oxidaseen_US
dc.subjectPBSen_US
dc.titleThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4en_US
dc.typeTexten_US
dc.typeReasearch Paperen_US
dc.contributor.departmentYoung Researchers Club, Quchan Branch, Islamic Azad University, Quchan, Iran.en_US
dc.contributor.departmentDepartment of Chemical Engineering, Quchan Branch, Islamic Azad University, Quchan, Islamic Republic of Iran.en_US
dc.citation.volume6
dc.citation.issue1
dc.citation.spage23
dc.citation.epage30


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد