نمایش مختصر رکورد

dc.contributor.authorBeitollai, Hadien_US
dc.contributor.authorGarkani Nejad, Faribaen_US
dc.contributor.authorTajik, Somayehen_US
dc.contributor.authorJahani, Shohrehen_US
dc.contributor.authorBiparva, Pouryaen_US
dc.date.accessioned1399-07-08T20:03:53Zfa_IR
dc.date.accessioned2020-09-29T20:03:53Z
dc.date.available1399-07-08T20:03:53Zfa_IR
dc.date.available2020-09-29T20:03:53Z
dc.date.issued2017-07-01en_US
dc.date.issued1396-04-10fa_IR
dc.date.submitted2017-02-11en_US
dc.date.submitted1395-11-23fa_IR
dc.identifier.citationBeitollai, Hadi, Garkani Nejad, Fariba, Tajik, Somayeh, Jahani, Shohreh, Biparva, Pourya. (2017). Voltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticles. International Journal of Nano Dimension, 8(3), 197-205.en_US
dc.identifier.issn2008-8868
dc.identifier.issn2228-5059
dc.identifier.urihttp://www.ijnd.ir/article_654805.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/80402
dc.description.abstractA novel electrochemical sensor was proposed for the determination of amitriptyline based on the copper oxide (CuO) nanoparticles modified graphite screen-printed electrode. CuO nanoparticles were used to enhance the surface area of the electrode and then improve the sensitivity of the electrochemical sensor. Amitriptyline electrochemical response characteristics of the modified electrode in a phosphate buffer solution (PBS) of pH 7.0 were investigated by cyclic voltammetry, differential pulse voltammetry and chronoamperometry. The linear range for the detection of amitriptyline was changed from 1.0 µM to 200.0 μM with the detection limit of 0.4 μM (S/N=3). Finally, the proposed method was applied to measure amitriptyline in real samples. It was shown that the proposed sensor exhibited significant promise as a reliable technique for the detection of amitriptyline in real samples.en_US
dc.format.extent694
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherIslamic Azad University-Tonekabon Branchen_US
dc.relation.ispartofInternational Journal of Nano Dimensionen_US
dc.subjectAmitriptylineen_US
dc.subjectCuO nanoparticlesen_US
dc.subjectElectrochemical sensoren_US
dc.subjectGraphite screen-printed electrodeen_US
dc.subjectVoltammetryen_US
dc.subjectMetal Oxide nanostructuresen_US
dc.subjectNanochemistryen_US
dc.subjectNanosensore and semiconductoren_US
dc.titleVoltammetric determination of amitriptyline based on graphite screen printed electrode modified with a Copper Oxide nanoparticlesen_US
dc.typeTexten_US
dc.typeReasearch Paperen_US
dc.contributor.departmentEnvironment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iranen_US
dc.contributor.departmentDepartment of Chemistry, Graduate University of Advanced Technology, Kerman, Iranen_US
dc.contributor.departmentEnvironment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iranen_US
dc.contributor.departmentEnvironment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iranen_US
dc.contributor.departmentDepartment of Basic Sciences, Sari Agricultural Sciences and Natural Resources University, Sari, Iranen_US
dc.citation.volume8
dc.citation.issue3
dc.citation.spage197
dc.citation.epage205


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد