نمایش مختصر رکورد

dc.contributor.authorBansal, Hemanten_US
dc.contributor.authorNayak, Tusharen_US
dc.contributor.authorKar, Santanuen_US
dc.contributor.authorSharma, ViJayen_US
dc.date.accessioned1399-10-19T15:38:48Zfa_IR
dc.date.accessioned2021-01-08T15:38:48Z
dc.date.available1399-10-19T15:38:48Zfa_IR
dc.date.available2021-01-08T15:38:48Z
dc.date.issued2021-01-01en_US
dc.date.issued1399-10-12fa_IR
dc.date.submitted2020-08-03en_US
dc.date.submitted1399-05-13fa_IR
dc.identifier.citationBansal, Hemant, Nayak, Tushar, Kar, Santanu, Sharma, ViJay. (2021). Concerns Regarding the Sufficiency of Isolated Buttress Plating in the Management of Posterior Wall Acetabular Fractures: Letter to the Editor. The Archives of Bone and Joint Surgery, 9(1), 133-134. doi: 10.22038/abjs.2020.50932.2524en_US
dc.identifier.issn2345-4644
dc.identifier.issn2345-461X
dc.identifier.urihttps://dx.doi.org/10.22038/abjs.2020.50932.2524
dc.identifier.urihttps://abjs.mums.ac.ir/article_17006.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/709563
dc.description.abstractWe read the recently published article [1] in your journal with great interest. This study has compared the efficacy of isolated buttress plate fixation with the combination of intra-wall/ lag screw and buttress plate in the surgical management of posterior wall acetabular fractures. The authors have highlighted the advantage of avoiding inadvertent intraarticular screw penetration and have also shown comparable outcomes with the use of isolated buttress plate. As the reader, we would like to put forward some concerns based on the study analysis.en_US
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciences, Iranian Society of Knee Surgery, Arthroscopy and Sports Tramatology,Iranian Orthopaedic Associationen_US
dc.relation.ispartofThe Archives of Bone and Joint Surgeryen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/abjs.2020.50932.2524
dc.subjectPosterior wallen_US
dc.subjectAcetabulumen_US
dc.subjectIsolateden_US
dc.subjectButtress Plateen_US
dc.titleConcerns Regarding the Sufficiency of Isolated Buttress Plating in the Management of Posterior Wall Acetabular Fractures: Letter to the Editoren_US
dc.typeTexten_US
dc.typeLETTER TO THE EDITORen_US
dc.contributor.departmentDepartment of Orthopedics, JPNATC, AIIMS, New Delhi, Indiaen_US
dc.contributor.departmentDepartment of Orthopedics, JPNATC, AIIMS, New Delhi, Indiaen_US
dc.contributor.departmentDepartment of Orthopedics, JPNATC, AIIMS, New Delhi, Indiaen_US
dc.contributor.departmentDepartment of Orthopedics, JPNATC, AIIMS, New Delhi, Indiaen_US
dc.citation.volume9
dc.citation.issue1
dc.citation.spage133
dc.citation.epage134
nlai.contributor.orcid0000-0003-0426-3804
nlai.contributor.orcid0000-0003-3707-0478


فایل‌های این مورد

فایل‌هااندازهقالبمشاهده

فایلی با این مورد مرتبط نشده است.

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد