    Vitamin E-Coated Polysulfone Membrane-Based Hemodiafiltration Attenuates Inflammation in a Rat Model of Lipopolysaccharide-Induced Systemic Inflammation

    (ندگان)پدیدآور
    Hatanaka, YoshihiroInoue, SatoruGoto, KojiYasuda, NorihisaHidaka, SeigoKitano, Takaaki
    Thumbnail
    نوع مدرک
    Text
    Original Article(s)
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: Acute blood purification (ABP) therapy is used regularly in the clinical setting and reportedly alleviates organ failure associated with severe systemic inflammatory responses, leading to reduced mortality. The present study aimed to determine whether there is a difference in efficacy between polysulfone (PS) membranes, which are currently used regularly in the clinical setting, and vitamin E-coated polysulfone (VEPS) membranes, which are anticipated to exhibit the antioxidant and anti-inflammatory properties of vitamin E.Methods: Male Wistar rats (n=15/group) were intravenously administered 10 mg/kg of lipopolysaccharide (LPS) to establish a systemic inflammatory response model. Six hours after LPS administration, hemodiafiltration (HDF) was performed for 30 minutes using a PS or VEPS membrane under general anesthesia. Blood was collected at various time points, lung tissue was evaluated histologically, and 24-hour survival was assessed.Results: The rats in the VEPS group tended to have a higher survival rate than those in the PS group when undergoing HDF, although the difference was not significant. With respect to lung tissue, the inflammatory response was suppressed to a greater extent in the VEPS group than the PS group. Serum interleukin (IL)-6 levels were reduced at an early stage, plasma antioxidant activity was increased, and oxidative stress was reduced in the VEPS group compared to the PS group.Conclusion: Relative to PS membrane-based HDF, the survival rate tended to improve and inflammation was subdued earlier due to the antioxidant activity and early attenuation of inflammation associated with VEPS membrane-based HDF.
    کلید واژگان
    Vitamin E
    Inflammatory response
    Polysulfone
    Hemodiafiltration
    Rats

    شماره نشریه
    5
    تاریخ نشر
    2017-09-01
    1396-06-10
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Medical Material Laboratory, Asahi Kasei Medical Company, Oaza-Sato, Oita, Japan
    Medical Material Laboratory, Asahi Kasei Medical Company, Oaza-Sato, Oita, Japan
    Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, Oita University, Idaigaoka-Hasamamachi, Yufu City, Oita, Japan
    Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, Oita University, Idaigaoka-Hasamamachi, Yufu City, Oita, Japan
    Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, Oita University, Idaigaoka-Hasamamachi, Yufu City, Oita, Japan
    Department of Anesthesiology and Intensive Care Medicine, Faculty of Medicine, Oita University, Idaigaoka-Hasamamachi, Yufu City, Oita, Japan

    شاپا
    0253-0716
    1735-3688
    URI
    https://ijms.sums.ac.ir/article_40483.html
    https://iranjournals.nlai.ir/handle/123456789/440067

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب