| dc.contributor.author | Gharehbaghi, M.M. | en_US |
| dc.contributor.author | Maamuri, G.A. | en_US |
| dc.contributor.author | Peirovifar, A. | en_US |
| dc.contributor.author | Boskabadi, H. | en_US |
| dc.contributor.author | Afshari, J.T. | en_US |
| dc.contributor.author | Shakeri, M.T. | en_US |
| dc.date.accessioned | 1399-07-30T20:59:35Z | fa_IR |
| dc.date.accessioned | 2020-10-21T20:59:36Z | |
| dc.date.available | 1399-07-30T20:59:35Z | fa_IR |
| dc.date.available | 2020-10-21T20:59:36Z | |
| dc.date.issued | 2007-12-01 | en_US |
| dc.date.issued | 1386-09-10 | fa_IR |
| dc.date.submitted | 2015-05-25 | en_US |
| dc.date.submitted | 1394-03-04 | fa_IR |
| dc.identifier.citation | Gharehbaghi, M.M., Maamuri, G.A., Peirovifar, A., Boskabadi, H., Afshari, J.T., Shakeri, M.T.. (2007). Immediate Diagnosis of Early Onset Sepsis in Premature Newborns by Measurement of Cord C-Reactive Protein and Interleukin-6. Iranian Journal of Medical Sciences, 32(4), 217-221. | en_US |
| dc.identifier.issn | 0253-0716 | |
| dc.identifier.issn | 1735-3688 | |
| dc.identifier.uri | https://ijms.sums.ac.ir/article_39966.html | |
| dc.identifier.uri | https://iranjournals.nlai.ir/handle/123456789/439754 | |
| dc.description.abstract | Background: The purpose of this study was to determine the relationship between early onset sepsis and increased levels of C-reactive protein (CRP) and interleukin-6 (IL-6) in cord plasma. Methods: A prospective study was conducted in 141 premature infants delivered with gestational ages of 26-35 weeks. IL-6 and CPR were measured by enzyme-linked immunoassay in the cord plasma of the neonates. According to clinical, laboratory findings and blood culture results, newborn infants were allocated into four groups (A-D): documented early onset infection, clinical sepsis, possible infection, and control groups respectively. Results: Mean IL-6 levels in group A-D was 264, 212, 160, and 33.3 pg/ml respectively. Difference between groups was statistically significant (p=.002). With cut off point of 18 pg/ml, the sensitivity and specificity of IL-6 for diagnosis of early onset sepsis was 72% and 55% respectively. There was not significant difference between mean levels of CRP among groups (p=0.28). Conclusion: Having considered the relatively good sensitivity and moderate specificity of cord IL-6, using this test can be recommended as a useful detector of early onset sepsis and non-infected sick neonates. | en_US |
| dc.language | English | |
| dc.language.iso | en_US | |
| dc.publisher | Shiraz University of Medical Sciences | en_US |
| dc.relation.ispartof | Iranian Journal of Medical Sciences | en_US |
| dc.title | Immediate Diagnosis of Early Onset Sepsis in Premature Newborns by Measurement of Cord C-Reactive Protein and Interleukin-6 | en_US |
| dc.type | Text | en_US |
| dc.type | Original Article(s) | en_US |
| dc.citation.volume | 32 | |
| dc.citation.issue | 4 | |
| dc.citation.spage | 217 | |
| dc.citation.epage | 221 | |