    High-Performance Hemodialysis Membrane: Influence of Polyethylene Glycol and Polyvinylpyrrolidone in the Polyethersulfone Membrane

    (ندگان)پدیدآور
    Hasheminasab, SomayehBarzin, JalalDehghan, Rahim
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    3.862 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    SI: Honoring AF
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    the preparation of high-performance hemodialysis membrane, the effect of polyethylene glycol (PEG), polyvinylpyrrolidone (PVP), and also the simultaneous effect of both additives in the polyethersulfone (PES) membrane were investigated. Viscosity measurements demonstrated that PVP has better compatibility with PES, owing to the amorphous nature, closer glassy transition temperature (Tg), and solubility parameters rather than PEG (semi-crystalline and low Tg). This could lead to enhancement in the solution viscosity. SEM results revealed that membranes morphology was dependent upon casting solution viscosity and with increasing viscosity; the formation of macro-voids suppressed and achieving to a membrane with a smaller mean pore size would be possible. The results of the AFM study demonstrated that, with the addition of PVP, membranes with smooth surface were achieved. In contrast, the PEG addition led to a rougher membrane surface. The results verified that PEG had a tangible effect on the permeability of membrane rather than PVP or blend of PVP and PEG, which is owing to its impressive pore-forming role. The maximum pure water permeability (PWP) was achieved for MV4 (24.9 L/m2.h.bar), MG2 (44.8 L/m2.h.bar), MVG2 (25.2 L/m2.h.bar), and MVG3 (25.1 L/m2.h.bar). Rejection test showed that MV3, MV4, MG3, MG4, MVG2, and MVG3 had the best performance in terms of urea removal and maintaining other components, especially bovine serum albumin (BSA). In-vitro cytotoxicity demonstrated the biocompatibility of MV2, MG3, and MVG3 as representative of all membranes. The lactate dehydrogenase (LDH) test confirmed that PVP has a tangible effect on the reduction of platelet adhesion on the membrane surface.
    کلید واژگان
    Hemodialysis membrane
    Polyethersulfone (PES)
    Polyvinylpyrrolidone (PVP)
    Polyethylene glycol (PEG)
    Biotechnology
    Formation/structure/performance
    Polymeric membranes

    شماره نشریه
    4
    تاریخ نشر
    2020-10-01
    1399-07-10
    ناشر
    FIMTEC & MPRL
    سازمان پدید آورنده
    Department of Biomaterials, Iran Polymer & Petrochemical Institute, Tehran, Iran
    Department of Biomaterials, Iran Polymer & Petrochemical Institute, Tehran, Iran
    Department of Biomaterials, Iran Polymer & Petrochemical Institute, Tehran, Iran

    شاپا
    2476-5406
    URI
    https://dx.doi.org/10.22079/jmsr.2020.128323.1391
    http://www.msrjournal.com/article_44474.html
    https://iranjournals.nlai.ir/handle/123456789/434880

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب