• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Electrochemistry
    • Volume 12, Issue 7
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Electrochemistry
    • Volume 12, Issue 7
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A Promising Enhanced Polymer Modified Voltammetric Sensor for the Quantification of Catechol and Phloroglucinol

    (ندگان)پدیدآور
    Manjunatha, Jamballi G.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.447 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In the present paper, poly(Tyrosine) modified graphene paste electrode (PTMGPE) was fabricated by utilizing an electropolymerization technique. Deposition of polymer film at bare graphene paste electrode (BGPE) was characterized by field emission scanning electron microscopy (FE-SEM). The PTMGPE was applied for Voltammetric detection of catechol (CC) and its quantification in phosphate buffer solutions of pH 7.0 (PBS). The detected cyclic voltammetric oxidation current of CC and phloroglucinol (PG) on PTMGPE is nearly 4 times higher with controlled over potential as a contrast to BGPE. This result shows the electrocatalytic effect of the poly (Tyrosine) layer. The differential pulse voltammetry (DPV) results show that CC and PG can be detected instantaneously using PTMGPE with peak separation of 0.300 V between CC and PG. Also, DPV showed two linear current responses in the concentration range of 2×10-6 to 1×10-5 M and 1.5×10-5 to 5×10-5 M with a coefficients of correlation 0.9951 and 0.9976 respectively. The detection limit (DL) and quantization limit (QL) were found to be 3.04×10-7 and 10×10-7 mol L-1 respectively. Further, we have also studied real sample analysis in tap water using proposed PTMGPE in the form of recovery studies and the achieved outcomes are found to be excellent agreement with the previous results. The PTMGPE shows exceptional selectivity, good sensitivity, and steadiness, making it as an attractive and alternative sensor for concurrent determination of CC and PG.
    کلید واژگان
    Catechol
    Phloroglucinol
    Poly (Tyrosine)
    Graphene paste electrode
    sensor
    Analysis

    شماره نشریه
    7
    تاریخ نشر
    2020-07-01
    1399-04-11
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Department of Chemistry, FMKMC College, Madikeri, Mangalore University Constituent College, Karnataka, India

    شاپا
    2008-4226
    URI
    http://www.abechem.com/article_43499.html
    https://iranjournals.nlai.ir/handle/123456789/432079

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب