• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Electrochemistry
    • Volume 12, Issue 3
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Analytical and Bioanalytical Electrochemistry
    • Volume 12, Issue 3
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    New Two-fold Amplified Electroanalytical Sensor for Determination of Xanthine in the Presences of Caffeine in Food Samples

    (ندگان)پدیدآور
    Dehdashtian, NiloofarShahidi, Seyed-AhmadBijad, Majedeh
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    656.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Fast and sensitive response electrochemical sensor based on CoFe2O4 nanoparticle and 1-buthyl-3-methyl imidazolium bromide room temperature ionic liquids carbon paste electrode (CoFe2O4/NP/ILs/CPE) is fabricated for the determination of Xanthine (Xt) in the presences of Caffeine in fish and fruit samples. In the first step, CoFe2O4/NP was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD) and results showed synthesized nanoparticle with diameter between 26.92-29.22 nm. The electro-oxidation of Xt and Caffeine occurred at a potential about 0.7 V and 1.1 V, which was much better in comparison with bare carbon paste electrode in phosphate buffer (pH=6.0) at the surface of the (CoFe2O4/NP/ILs/CPE). Other electrochemical techniques were also investigated including cyclic voltammetry, differential pulse voltammetry (DPV) and chronoamperometry at CoFe2O4/NP/ILs/CPE. At optimized conditions for Xt and Caffeine analysis, DPV peak currents showed a wide linear dynamic ranging from 8.0 nM to 500 μM and detection limit for Xt was 3.0 nM and of course we obtained good dynamic range between 0.1 to 300 μM and good limit of detection 0.05 μM for caffeine. As a result, the proposed electrode could determine Xt in the presences of Caffeine in real samples with good selectivity and high sensitivity.
    کلید واژگان
    Xanthine
    Caffeine
    Carbon paste electrode
    Fish samples
    Fruit samples

    شماره نشریه
    3
    تاریخ نشر
    2020-03-01
    1398-12-11
    ناشر
    University of Tehran
    سازمان پدید آورنده
    Department of Food Science and Technology, Faculty of Agriculture and Food Science, Ayatollah Amoli Branch, Islamic Azad University, Amol, Iran

    شاپا
    2008-4226
    URI
    http://www.abechem.com/article_38850.html
    https://iranjournals.nlai.ir/handle/123456789/432039

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب