Fatal Cobalt Cardiomyopathy Following Revision Total Hip Arthroplasty – A Brief Report with Review of Literature
(ندگان)پدیدآور
Gautam, DeepakPande, AshishMalhotra, Rajeshنوع مدرک
TextCASE REPORT
زبان مدرک
Englishچکیده
Ceramic bearing surfaces are being increasingly used in young patients undergoing total hip arthroplasty. However,failures have been reported including fractures even with the newer third generation ceramics. The recommendedtreatment for fracture of ceramic bearing surfaces is complete synovectomy and revision total hip arthroplasty.However, disappointing results have also been reported with this approach. The residual ceramic particles may leadto complications. We report a fatal case of cobalt toxicity leading to cardiomyopathy secondary to the catastrophicfailure of a Cobalt-Chrome femoral head, which followed the revision of a fractured ceramic-on-ceramic total hiparthroplasty.Level of evidence: IV
کلید واژگان
Ceramic head fractureCobalt Toxicity
Fatal cardiomyopathy
Metal on Polyethylene
Revision hip arthroplasty
Arthroscopy & Arthroplasty.
شماره نشریه
4تاریخ نشر
2019-07-011398-04-10
ناشر
Mashhad University of Medical Sciences, Iranian Society of Knee Surgery, Arthroscopy and Sports Tramatology,Iranian Orthopaedic Associationسازمان پدید آورنده
Department of Orthopedics, All India Institute of Medical Sciences (AIIMS), New Delhi, IndiaDepartment of Orthopedics, Military Hospital, Kirkee, Pune, India
Department of Orthopedics, All India Institute of Medical Sciences (AIIMS), New Delhi, India
شاپا
2345-46442345-461X