نمایش مختصر رکورد

dc.contributor.authorBashti, Kavehen_US
dc.contributor.authorTahmasebi, Mohammad Naghien_US
dc.contributor.authorKaseb, Hasanen_US
dc.contributor.authorFarahmand, Farzamen_US
dc.contributor.authorAkbar, Mohammaden_US
dc.contributor.authorMobini, Amiren_US
dc.date.accessioned1399-07-09T12:56:33Zfa_IR
dc.date.accessioned2020-09-30T12:56:33Z
dc.date.available1399-07-09T12:56:33Zfa_IR
dc.date.available2020-09-30T12:56:33Z
dc.date.issued2015-01-01en_US
dc.date.issued1393-10-11fa_IR
dc.date.submitted2014-08-03en_US
dc.date.submitted1393-05-12fa_IR
dc.identifier.citationBashti, Kaveh, Tahmasebi, Mohammad Naghi, Kaseb, Hasan, Farahmand, Farzam, Akbar, Mohammad, Mobini, Amir. (2015). Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery. The Archives of Bone and Joint Surgery, 3(1), 29-34. doi: 10.22038/abjs.2015.3826en_US
dc.identifier.issn2345-4644
dc.identifier.issn2345-461X
dc.identifier.urihttps://dx.doi.org/10.22038/abjs.2015.3826
dc.identifier.urihttp://abjs.mums.ac.ir/article_3826.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/431423
dc.description.abstract<br/><span style="font-size: xx-small;">Background: </span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular </span></span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. </span></span><br/><span style="font-size: xx-small;">Purposes: </span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compare its biomechanical features with conventional absorbable interference screw technique in a bovine model. </span></span><br/><span style="font-size: xx-small;">Methods: </span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">Twenty pairs of bovine knees were harvested after death. Soft tissue was removed and the Achilles tendon was harvested to be used as an ACL graft. It was secured into the bone tunnel on the tibial side via two different </span></span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">methods: Bashti Bone Plug technique and conventional screw method. Biomechanical strength was measured using 200 N and 300 N cyclic loading on the graft. Pull out strength was also tested until the graft fails. </span></span><br/><span style="font-size: xx-small;">Results: </span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">No graft failure was observed after 200 N and 300 N cyclic loading in either fixation methods. When testing for pull out failure, 21 tendons (53%) were torn and 19 tendons (48%) slipped out. No fixation failure occurred, which did not reveal a significant difference between the bone plug or interference screw group (</span></span><em><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">P</span></span></em><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">=0.11). The mean pull out </span></span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">force until failure of the graft was 496±66 N in the screw group and 503±67 N in the bone plug group (</span></span><em><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">P</span></span></em><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">=0.76). </span></span><br/><span style="font-size: xx-small;">Conclusions: </span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">Our suggested fixation technique of Bashti bone plug is a native, cheap, and feasible method that provides comparable biomechanical strength with interference screw when soft tissue fixation was attempted in bovine </span></span><span style="font-family: Arial,Arial; font-size: xx-small;"><span style="font-family: Arial,Arial; font-size: xx-small;">model. </span></span>en_US
dc.format.extent566
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherMashhad University of Medical Sciences, Iranian Society of Knee Surgery, Arthroscopy and Sports Tramatology,Iranian Orthopaedic Associationen_US
dc.relation.ispartofThe Archives of Bone and Joint Surgeryen_US
dc.relation.isversionofhttps://dx.doi.org/10.22038/abjs.2015.3826
dc.subjectanterior cruciate ligamenten_US
dc.subjectBashtien_US
dc.subjectBiomechanical strengthen_US
dc.subjectBone plugen_US
dc.subjectBovine modelen_US
dc.subjectInitial fixationen_US
dc.subjectInterference screwen_US
dc.subjectReconstructionen_US
dc.titleBiomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgeryen_US
dc.typeTexten_US
dc.typeRESEARCH PAPERen_US
dc.contributor.departmentTehran university of medical sciencesen_US
dc.contributor.departmentTehran university of medical sciences,Shariati hospitalen_US
dc.contributor.departmentTehran university of medical sciences,Emam hospitalen_US
dc.contributor.departmentSharif university of technology.School of biomechanicsen_US
dc.contributor.departmentSharif university of technology,school of biomechanicsen_US
dc.contributor.departmentSharif university of technology, school of bimechanicsen_US
dc.citation.volume3
dc.citation.issue1
dc.citation.spage29
dc.citation.epage34
nlai.contributor.orcid0000-0003-4644-6756
nlai.contributor.orcid0000-0001-8900-7003


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد