Experimental Energy and Exergy Analysis of a Flat Plate Solar Water Heater to Find Optimum Collector Mass Flow Rate
(ندگان)پدیدآور
Khanmohammadi, S.Veysi, F.Amini, S.نوع مدرک
TextOriginal Article
زبان مدرک
Englishچکیده
This paper presents the experimental study of a flat plate solar collector to find the optimum flow rate of collector with variation of daily solar radiation intensity. The procedure of ASHRAE standard was used for testing the thermal performance of flat-plate solar collector. Results show that using optimal collector flow rate can improve energy and exergy efficiency of SWH. Furthermore, results show that in no load on storage tank overall energy efficiency can improve between 0.25 % and 7 %. In addition, calculations show an increment between 0.18 % and 1.12% for overall exergy efficiency. In the 36 L/h, and 52 L/h and 72 L/h thermal load on storage tank overall energy and exergy efficiency show a reasonable increment with using optimum flow rate of collector. Finally, these experimental analysis results can be a base for design a collector flow rate controller to have a more efficient SWH.
کلید واژگان
SWHcollector flow rate
exergy efficiency
optimum flow rate
شماره نشریه
3تاریخ نشر
2018-07-011397-04-10
ناشر
University of Tehranسازمان پدید آورنده
Department of Mechanical Engineering, Kermanshah University of Technology, Kermanshah, IranDepartment of Mechanical Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran
Department of Mechanical Engineering, Faculty of Engineering, Razi University, Kermanshah, Iran
شاپا
2588-30972588-3100