• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Advances in Environmental Technology
    • Volume 5, Issue 2
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Advances in Environmental Technology
    • Volume 5, Issue 2
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A comparative study of the effect of compost/woodchips mixture, natural zeolite and zeolite/activated carbon mixture as packing materials on the biofilter performance

    (ندگان)پدیدآور
    narooei, elhamMohebbi-Kalhori, DavodSamimi, AbdolrezaZivdar, Mortaza
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.384 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Paper
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    The removal of formaldehyde from contaminated air was investigated via three laboratory-scale biofilters packed with different materials: a mixture of compost and woodchips (І), the natural clinoptilolite zeolite particles in the original form (II), and the mixture of zeolite/activated carbon (III). The biofilters were inoculated using aerobic sludge. The average removal efficiencies of 97.5%, 90%, and 93.5% were obtained at a 100 s empty bed residence time (EBRT) and 20 mg/m3 inlet concentration of formaldehyde for the biofilter of configurations І, II, and III, respectively. Also, the performance of the reactors was investigated at different EBRTs of 20, 30, 60, and 100 s, and the maximum elimination capacity of 2840 mg/m3.h was achieved at the lowest EBRT (20 s) for the biofilter of configuration II. Increasing the inlet formaldehyde concentration from 20 mg/m3 to 80 mg/m3 led to the maximum formaldehyde removal efficiency of 82% for the biofilter of configuration III. Therefore, a comparison of the results of the biofilters' performances showed that the biofilter of configuration III had the best performance, which was validated by obtaining a higher mass transfer coefficient. However, the biofilter of configurations II and III achieved steady-state conditions in a shorter time.
    کلید واژگان
    Biofilter
    Biodegradation
    Formaldehyde
    Packing materials
    Contaminated air
    air quality and pollution control

    شماره نشریه
    2
    تاریخ نشر
    2019-04-01
    1398-01-12
    ناشر
    Iranian Research Organization for Science and Technology
    سازمان پدید آورنده
    Chemical Engineering Department, University of Sistan and Baluchestan, Zahedan, Iran
    Chemical Engineering Department, Faculty of Engineering, University of Sistan and Baluchestan
    Department of Chemical Engineering, University of Sistan and Baluchestan, Zahedan, Iran
    Department of Chemical Engineering, Faculty of Engineering, University of Sistan and Baluchestan, Zahedan, Iran

    شاپا
    2476-6674
    2476-4779
    URI
    https://dx.doi.org/10.22104/aet.2020.3973.1198
    http://aet.irost.ir/article_898.html
    https://iranjournals.nlai.ir/handle/123456789/427341

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب