    Performance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT

    (ندگان)پدیدآور
    Matsutomo, NorikazuNagaki, AkioSasaki, Masayuki
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.460 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between conventional and IQSPECT in patients with coronary artery disease (CAD). Methods: Fifty-three patients undergoing rest-gated MPI for the evaluation of known or suspected coronary artery disease were enrolled in this study. In each patient, conventional SPECT (99mTc-tetrofosmin, 9.6 min; 201Tl, 12.9 min) was performed, immediately followed by IQSPECT, using a short acquisition time (4.3 min for 99mTc-tetrofosmin and 6.2 min for 201Tl). A quantitative analysis was performed on an MPI polar map using a 20-segment model of the left ventricle. An automated analysis by gated SPECT was carried out to determine the left ventricular volume and function, including the end-diastolic volume, end-systolic volume and left ventricular ejection fraction (LVEF). The degree of concordance between conventional SPECT and IQ-SPECT images was evaluated according to linear regression and Bland-Altman analyses. Results: The segmental percent uptake exhibited a significant correlation between IQSPECT and conventional SPECT (P  Conclusion: According to the 99mTc‐tetrofosmin and 201Tl protocols, IQ‐SPECT images were comparable to and in agreement with conventional SPECT images. Our results suggest that IQ‐SPECT is a useful technology for MPI SPECT, and can lead to an increase in scan efficiency and patient comfort.
    کلید واژگان
    Multi-focus fan beam collimator
    myocardial perfusion imaging
    comparable images and Resolution recovery reconstruction
    Cardiology
    Image Quantification
    Nuclear Medicine

    شماره نشریه
    2
    تاریخ نشر
    2014-10-01
    1393-07-09
    ناشر
    Asia Oceania Federation of Nuclear Medicine & Biology
    سازمان پدید آورنده
    Department of Radiology, Kurashiki Central Hospital/ Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University
    Department of Radiology, Kurashiki Central Hospital
    Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University

    شاپا
    2322-5718
    2322-5726
    URI
    http://aojnmb.mums.ac.ir/article_3037.html
    https://iranjournals.nlai.ir/handle/123456789/420956

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب