• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 6, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 6, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    A simple non-invasive I-123-IMP autoradiography method developed by modifying the simple non-invasive I-123-IMP microsphere method

    (ندگان)پدیدآور
    Ofuji, AsatoNagaoka, RiekoYamashita, KosukeTakaki, AkihiroIto, Shigeki
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    871.1کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Technical note
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: We developed a simple non-invasive I-123-N-isopropyl-p-iodoamphetamine (123I-IMP) quantification method by analyzing chest RI-angiography and single photon emission computed tomography (SPECT) images based on the microsphere model (SIMS method). Theoretically, the SIMS method could be changed to the simple non-invasive ARG (SIARG) method by modifying the integrated washout ratio (WR) to one-point WR. If the regional cerebral blood flow (rCBF) values derived from the SIARG and ARG methods correlate well, the facilities employing the ARG method can easily switch to the SIARG method. The purpose of this study was to develop the SIARG method by modifying the SIMS method and to confirm the feasibility of this method. Methods: The correlation between the input counts of the SIARG method and the blood counts was determined by linear regression analysis. The rCBF values determined by the SIARG method were compared with the values obtained with the ARG and SIMS methods. Results: There was a good linear correlation between the SIARG counts and the arterial blood counts obtained by the ARG method (r = 0.85, p Conclusions: The rCBF values obtained by the ARG, SIARG, and SIMS methods correlated very well. Therefore, the SIARG method is potentially useful for examinations in routine clinical practice.
    کلید واژگان
    123I-IMP
    SPECT
    rCBF
    auto-radiography (ARG) method
    non-invasive method
    Nuclear Medicine

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Asia Oceania Federation of Nuclear Medicine & Biology
    سازمان پدید آورنده
    Graduate School of Health Sciences, Kumamoto University, Kumamoto , Japan
    Department of Radiology, Clinical Research Institute, National Hospital Organization Kyushu Medical Center, Jigyouhama 1-8-1, Chuo-ku, Fukoka 810-8563, Japan
    Fujifilm RI Pharma Co.,Ltd. 14-1Kyobashi, 2-choume, chuo-ku, Tokyo, 104-0031, Japan
    Faculty of Life Sciences, Kumamoto University, Kuhonji 4-24-1, Chuo-ku, Kumamoto 862-0796, Japan
    Department of Medical Imaging, Faculty of Life Sciences, Kumamoto University, Kuhonji 4-24-1, Kumamoto 862-0796, Japan

    شاپا
    2322-5718
    2322-5726
    URI
    https://dx.doi.org/10.22038/aojnmb.2017.9555
    http://aojnmb.mums.ac.ir/article_9555.html
    https://iranjournals.nlai.ir/handle/123456789/420901

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب