    Comparison of TOF-PET and Bremsstrahlung SPECT images of Yttrium-90: A Monte Carlo Simulation Study

    (ندگان)پدیدآور
    Takahashi, AkihikoHimuro, KazuhikoBaba, ShingoYamashita, YasuoSasaki, Masayuki
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.745 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective(s): Yttrium-90 (90Y) is a beta particle nuclide used in targeted radionuclide therapy which is available to both single-photon emission computed tomography (SPECT) and time-of-flight (TOF) positron emission tomography (PET) imaging. The purpose of this study was to assess the image quality of PET and Bremsstrahlung SPECT by simulating PET and SPECT images of 90Y using Monte Carlo simulation codes under the same conditions and to compare them. Methods: In-house Monte Carlo codes, MCEP-PET and MCEP-SPECT, were employed to simulate images. The phantom was a torso-shaped phantom containing six hot spheres of various sizes. The background concentrations of 90Y were set to 50, 100, 150, and 200 kBq/mL, and the concentrations of the hot spheres were 10, 20, and 40 times of those of the background concentrations. The acquisition time was set to 30 min, and the simulated sinogram data were reconstructed using the ordered subset expectation maximization method. The contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR) were employed to evaluate the image qualities. Results: The CRC values of SPECT images were less than 40%, while those of PET images were more than 40% when the hot sphere was larger than 20 mm in diameter. The CNR values of PET images of hot spheres of diameter smaller than 20 mm were larger than those of SPECT images. The CNR values mostly exceeded 4, which is a criterion to evaluate the discernibility of hot areas. In the case of SPECT, hot spheres of diameter smaller than 20 mm were not discernable. On the contrary, the CNR values of PET images decreased to the level of SPECT, in the case of low concentration. Conclusion: In almost all the cases examined in this investigation, the quantitative indexes of TOF-PET 90Y images were better than those of Bremsstrahlung SPECT images. However, the superiority of PET image became critical in the case of low activity concentrations.
    کلید واژگان
    90Y
    TOF-PET
    Bremsstrahlung SPECT
    Monte Carlo Simulation
    Image processing
    Nuclear Medicine

    شماره نشریه
    1
    تاریخ نشر
    2018-01-01
    1396-10-11
    ناشر
    Asia Oceania Federation of Nuclear Medicine & Biology
    سازمان پدید آورنده
    Department of Health Sciences, Faculty of Medical Sciences, Kyushu University
    Division of Radiology, Department of Medical Technology, Kyushu University Hospital
    Department of Clinical Radiology, Kyushu University Hospital, Fukuoka, Japan
    Division of Radiological Technology, Department of Medical Technology, Kyushu University Hospital
    Department of Health Sciences, Graduate School of Medical Sciences, Kyushu University

    شاپا
    2322-5718
    2322-5726
    URI
    https://dx.doi.org/10.22038/aojnmb.2017.9673
    http://aojnmb.mums.ac.ir/article_9673.html
    https://iranjournals.nlai.ir/handle/123456789/420898

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب