• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 3, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asia Oceania Journal of Nuclear Medicine and Biology
    • Volume 3, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Dual radioisotopes simultaneous SPECT of 99mTc-tetrofosmin and 123I-BMIPP using a semiconductor detector.

    (ندگان)پدیدآور
    Takahashi, YasuyukiMiyagawa, MasaoNishiyama, YoshikoKawaguchi, NaotoIshimura, HayatoMochizuki, Teruhito
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    723.8کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective(s): The energy resolution of a cadmium-zinc-telluride (CZT) solid-state semiconductor detector is about 5%, and is superior to the resolution of the conventional Anger type detector which is 10%. Also, the window width of the high-energy part and of the low-energy part of a photo peak window can be changed separately. In this study, we used a semiconductor detector and examined the effects of changing energy window widths for 99mTc and 123 I simultaneous SPECT. Methods: The energy “centerline" for 99mTc was set at 140.5 keV and that for 123I at 159.0 keV. For 99mTc, the “low-energy-window width" was set to values that varied from 3% to 10% of 140.5 keV and the “high-energy-window width" were independently set to values that varied from 3% to 6% of 140.5 keV. For 123I, the “low energy-window-width" varied from 3% to 6% of 159.0 keV and the high-energy-window width from 3% to 10% of 159 keV. In this study we imaged the cardiac phantom, using single or dual radionuclide, changing energy window width, and comparing SPECT counts as well as crosstalk ratio. Results: The contamination to the 123I window from 99mTc (the crosstalk) was only 1% or less with cutoffs of 4% at lower part and 6% at upper part of 159KeV. On the other hand, the crosstalk from 123I photons into the 99mTc window mostly exceeded 20%. Therefore, in order to suppress the rate of contamination to 20% or less, 99mTc window cutoffs were set at 3% in upper part and 7% at lower part of 140.5 KeV. The semiconductor detector improves separation accuracy of the acquisition inherently at dual radionuclide imaging. In, this phantom study we simulated dual radionuclide simultaneous SPECT by 99mTc-tetrofosmin and 123 I-BMIPP. Conclusion: We suggest that dual radionuclide simultaneous SPECT of 99mTc and 123I using a CZT semiconductor detector is possible employing the recommended windows.
    کلید واژگان
    Semiconductor detector
    Energy resolution
    Dual radioisotopes simultaneous SPECT
    123I-BMIPP
    Image processing
    Image Quantification

    شماره نشریه
    1
    تاریخ نشر
    2015-01-01
    1393-10-11
    ناشر
    Asia Oceania Federation of Nuclear Medicine & Biology
    سازمان پدید آورنده
    Department of Nuclear Medicine Technology, Gunma Prefectural College of Health Sciences, Maebashi, Japan
    Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
    Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
    Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan
    Department of Radiological Technology, Ehime University Hospital, Toon, Japan
    Department of Radiology, Ehime University Graduate School of Medicine, Toon, Japan

    شاپا
    2322-5718
    2322-5726
    URI
    https://dx.doi.org/10.7508/aojnmb.2015.01.007
    http://aojnmb.mums.ac.ir/article_3081.html
    https://iranjournals.nlai.ir/handle/123456789/420868

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب