Calculation of dose uniformity ratio in irradiation cell of GC-220 using analytical method based on multipole moment expansion
(ندگان)پدیدآور
Rezaeian, PeimanAtaenia, VahidehShafiei, Sepidehنوع مدرک
TextOriginal Article
زبان مدرک
Englishچکیده
In this paper, dose uniformity ratio in irradiation cell of GC-220 is specifiedutilizing an analytical method based on the multipole moment expansion. In this method, the values of monople, dipole and quadrupole moments for source arrangements of GC-220 are calculated by numerical integrating. Appling these values, the dose uniformity ratio in the irradiation cell of GC-220 is calculated equal to 1.92. Monte Carlo simulation is applied to validate calculations. There is a relative difference about 12% between the results obtained from the analytical calculation and Monte Carlo simulation, which confirm the used method. In comparison with Monte Carlo methods, this method is not time consuming, so, this method can be used for the conceptual designing and the source load planning of irradiators.
کلید واژگان
Dose Uniformity RatioMutipole Moment Expansion
Monte Carlo Method
Gamma Cell 220
Source Load Planning
شماره نشریه
1تاریخ نشر
2020-01-011398-10-11
ناشر
K. N. Toosi University of Technologyسازمان پدید آورنده
Radiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box 11365-3486, Tehran, IranRadiation Applications Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box 11365-3486, Tehran, Iran
Physics and Accelerators Research School, Nuclear Science and Technology Research Institute, AEOI, PO Box 11365-3486, Tehran, Iran
شاپا
2645-63972645-5188