نمایش مختصر رکورد

dc.contributor.authorYazdanpanah, Omiden_US
dc.contributor.authorIzadifard, Ramezan Alien_US
dc.contributor.authorAbdi Moghadam, Mehrdaden_US
dc.date.accessioned1399-07-09T11:47:49Zfa_IR
dc.date.accessioned2020-09-30T11:47:49Z
dc.date.available1399-07-09T11:47:49Zfa_IR
dc.date.available2020-09-30T11:47:49Z
dc.date.issued2016-08-01en_US
dc.date.issued1395-05-11fa_IR
dc.date.submitted2017-01-02en_US
dc.date.submitted1395-10-13fa_IR
dc.identifier.citationYazdanpanah, Omid, Izadifard, Ramezan Ali, Abdi Moghadam, Mehrdad. (2016). Embedded Crack Identification in Beam-Column Structures Under Axial Load Using an Efficient Static Data Based Indicator. Journal of Rehabilitation in Civil Engineering, 4(2), 67-78. doi: 10.22075/jrce.2017.1842.1160en_US
dc.identifier.issn2345-4415
dc.identifier.issn2345-4423
dc.identifier.urihttps://dx.doi.org/10.22075/jrce.2017.1842.1160
dc.identifier.urihttps://civiljournal.semnan.ac.ir/article_2297.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/409268
dc.description.abstractA triangular model base on an investigation which has done by Sinha et al. has been developed for evaluating embedded crack localization in beam-column structures. In the assessment of this member's behavior, the effects of displacement slope are necessary. In order to propose a crack localization method for embedded crack, an efficient static data based indicator is proposed for this crack in Euler-Bernoulli beam-columns under axial load effect. A finite element procedure is implemented for calculating the Static responses. Then, base on a central finite difference method, the slope and curvatures of horizontal displacements are evaluated. For this purpose, a simply supported beam-column and a two-span beam-column are considered and two different scenarios base on the damage of one element (single damage) and multiple elements (multiple damages) by considering the noise have been assessed. The numerical results have shown that this crack localization method has considerable accurate.en_US
dc.format.extent734
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherSemnan Universityen_US
dc.relation.ispartofJournal of Rehabilitation in Civil Engineeringen_US
dc.relation.isversionofhttps://dx.doi.org/10.22075/jrce.2017.1842.1160
dc.subjectCrack modelingen_US
dc.subjectEmbedded crack detectionen_US
dc.subjectBeam-column structureen_US
dc.subjectAxial loaden_US
dc.subjectStatic responsesen_US
dc.subjectStructural Health Monitoringen_US
dc.titleEmbedded Crack Identification in Beam-Column Structures Under Axial Load Using an Efficient Static Data Based Indicatoren_US
dc.typeTexten_US
dc.typeRegular Paperen_US
dc.contributor.departmentPh.D. Student, Faculty of Engineering, Imam Khomeini International University, Qazvin, Iranen_US
dc.contributor.departmentAssistant Professor, Faculty of Engineering, Imam Khomeini International University, Qazvin, Iranen_US
dc.contributor.departmentPh.D. Student, Faculty of Engineering, Imam Khomeini International University, Qazvin, Iranen_US
dc.citation.volume4
dc.citation.issue2
dc.citation.spage67
dc.citation.epage78
nlai.contributor.orcid0000-0002-7770-8010


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد