    Comparison of Fracture Strength between two Systems: IPS Empress 2 and IPS E.max press

    (ندگان)پدیدآور
    Jalalian, E.Moghaddam, L.Sadegh, M.
    Thumbnail
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Statement of  problem: One of the major problems of all-ceramic restorations is their probable fracture against lateral forces. However there is not enough information about fracture strength of various all-ceramic restorations.Propose: The aim of this experimental research was to compare the fracture strength and the most probable fracture points in all-ceramic restorations.Materials and methods: In this laboratory-based experimental study, 10 symmetric crowns from each IPS Empress2 and IPS e.max press system were constructed on a laboratory model for maxillary central incisor with 2mm occlusal reduction and deep chamfer finishing line. The core thickness was between 0.7-0.8 mm and porcelain was placed over the core using the layering technique. Each of the crowns was cemented onto the dye using Dual cure Variolink II cement and were imposed to compressive forces in Universal testing machine (V=1mm/min) at 30 degrees angle in palatal surface until the fracture occurred. Then the samples were inspected for fracture points by observation. The statistical evaluations were done with Independent Sample T-test (α=0.05).Result: The average force leading to fracture was 385 N (SD=79/96) for IPS Empress2 and 380 N (SD=106/28) for IPS e.max press. The most common fracture points in two groups were the incisal edge and buccal surface. There was no meaningful statistical difference in fracture force between the two systems (P>0.05).Conclusion: The findings of this research indicated that there is no meaningful statistical difference between these two systems in their fracture strength.therefor they are both suitable for constructing anterior all-ceramic restorations.Key words: Crown, All-ceramic, Fracture strength

    شماره نشریه
    1
    تاریخ نشر
    2008-03-01
    1386-12-11
    ناشر
    Shiraz University of Medical Sciences
    سازمان پدید آورنده
    Associate professor of fixed prosthodontics department of azad University-dental branch
    Dentist
    Student

    شاپا
    2345-6485
    2345-6418
    URI
    https://dentjods.sums.ac.ir/article_41398.html
    https://iranjournals.nlai.ir/handle/123456789/400517

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب