    Performance Indices of Needle Biopsy Procedures for the Assessment of Screen Detected Abnormalities in Services Accredited by BreastScreen Australia

    (ندگان)پدیدآور
    پدیدآور نامشخص
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    442.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: We wished to analyse patterns of use of needle biopsy procedures by BreastScreen Australia(BSA) accredited programs to identify areas for improvement. Design: BSA services provided anonymous dataregarding percutaneous needle biopsy of screen detected lesions assessed between 2005-2009. Results: 12 services,from 5 of 7 Australian states and territories provided data for 18212 lesions biopsied. Preoperative diagnosis rateswere 96.84% for lesion other than microcalcification (LOTM) and 93.21% for microcalcifications. At surgery97.9% impalpable lesions were removed at the first procedure. Of 11548 Microcalcification (LOTM) biopsied,46.9% were malignant. The final diagnosis was reached by conventional core biopsy (CCB) in 72.46%, FNAB in21.33%, VACB in 1.69% and open biopsy in 4.52% of lesions. FNA is being limited to LOTM with benign imagingAfter FNAB, core biopsy was required for 38% of LOTM. In LOTM the mean false positive rate (FPR) was0.36% for FNAB, 0.06% for NCB and 0% for VACB. Diagnostic accuracy was 72.75% for FNAB and 92.1% forcore biopsies combined. Of 6441 microcalcifications biopsied 2305 (35.8%) were malignant. Microcalcificationsare being assessed primarily by NCB but 6.57% underwent FNAB, 45.6% of which required NCB. False positivediagnoses were rare. FNR was 5% for NCB and 1.53% for VACB. Diagnostic accuracy was 73.52% for FNAB,86.29% for NCB and 88.63% for VACB. Only 8 of 12 services had access to VACB facilities. Conclusions: BSAservices are selecting lesions effectively for biopsy and are achieving high preoperative diagnosis rates. Gaps inthe present accreditation standards require further consideration.
    کلید واژگان
    breast cancer
    Screening
    mammography
    needle biopsy

    شماره نشریه
    24
    تاریخ نشر
    2014-12-01
    1393-09-10
    ناشر
    West Asia Organization for Cancer Prevention (WAOCP)

    شاپا
    1513-7368
    2476-762X
    URI
    http://journal.waocp.org/article_30328.html
    https://iranjournals.nlai.ir/handle/123456789/39954

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب