• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asian Pacific Journal of Cancer Prevention
    • Volume 20, Issue 12
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Asian Pacific Journal of Cancer Prevention
    • Volume 20, Issue 12
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Is High Definition MLC Dosimetrically Superior to Standard Definition MLC for SIB-SBRT for Carcinoma Prostate

    (ندگان)پدیدآور
    T K, BijinaGanesh, K MA, Pichandi
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    432.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Articles
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective: The study was conducted to quantitatively evaluate the dosimetric effects of high definition (2.5 mm) and standard definition (5.0 mm) MLC on the quality of SBRT plans using SIB-IMRT and SIB-VMAT technique for carcinoma prostate and also to evaluate the dosimetric advantage of one technique over the other. Materials and Methods: Seventeen annonymized planning CT data sets were used to generate plans for both VMAT and IMRT techniques using 2.5 mm and 5.0 mm MLC.The prescription to the nodule was 45Gy in 5 fractions and to the prostate was 35Gy in 5 fractions.CI, GI, D2%, D98%, D50% and V95% for target; D2%, Dmean, V80%, V20% for OAR's; V5% of the irradiated volume, and delivered MU's were analyzed.An independent t-test was used to compare the plans. Patient specific QA for all plans were also performed and analyzed. Results: Minor difference in dosimetric indices was observed between 2.5mm and 5mm MLC VMAT plans, except D2% (PTV35) and D98% (GTV45) were better in 2.5mm MLC plans (p
    کلید واژگان
    VMAT
    MLC
    prostate
    SIB
    SBRT

    شماره نشریه
    12
    تاریخ نشر
    2019-12-01
    1398-09-10
    ناشر
    West Asia Organization for Cancer Prevention (WAOCP)
    سازمان پدید آورنده
    Research and Development Center, Bharathiar University, Coimbatore, India.
    Department of Radiation Physics, Kidwai Memorial Institute of Oncology, Bangalore, India.
    Department of Radiation Oncology, Healthcare Global Enterprises, Bangalore, India.

    شاپا
    1513-7368
    2476-762X
    URI
    https://dx.doi.org/10.31557/APJCP.2019.20.12.3817
    http://journal.waocp.org/article_88875.html
    https://iranjournals.nlai.ir/handle/123456789/36555

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب