    Dosimetric Validation of Volumetric Modulated Arc Therapy with Three 6MV Beam-Matched Linear Accelerators

    (ندگان)پدیدآور
    Ashokkumar, SangaiahGanesh, K MRamalingam, kKarthikeyan, KJagadeeshkumar, N
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    458.6کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Research Articles
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Background: To avoid inconvenience to patients due to linear accelerator down time in busy radio-therapy departments, treatment plans can be switched between linear accelerators provided that all exhibit the same same dosimetric characteristics. In other words linear accelerators should be beam-matched. Aim: The aim of this study was to evaluate the clinical significance of beam-matching using VMAT plans. Materials and Methods: Dosimetric data with a 6MV beam from am Clinac 2100CD were taken as baseline values and other two units, a 2300CD and a Unique Performance, were factory tuned in accordance. An analysis of PDD data was performed for different field sizes to evaluate energy matching. Beam profiles for field sizes of 10×10 cm2 and 40 × 40 cm2 at depths of 1.5 cm and 10 cm were analyzed. The relative output factor and MLC dosimetric properties were compared with each machine to determine variability among the different models. Thirty patients from our database were selected, ten each for head and neck, thorax and pelvis sites. VMAT plans were created in the Eclipse treatment planning system for a Clinac 2100 CD for reference. and verification plans were created for each to compare point dose measurements. Results: The TPR 20/10 for 10 × 10 cm2 was well matched, showing no energy differences. Deviation of all point dose measurements fell within ±3%. Planar dose maps all showed greater than 95% of points with a passed area γ-value less than 1. Conclusion: Our study evaluation of beam matching with treatment planning modeling showed good agreement fior 6 MV beams across all three linear accelerators used in our clinical environment.
    کلید واژگان
    VMAT
    AAA
    TPS
    Beam Matching
    Radiation oncology

    شماره نشریه
    12
    تاریخ نشر
    2017-12-01
    1396-09-10
    ناشر
    West Asia Organization for Cancer Prevention (WAOCP)
    سازمان پدید آورنده
    Research and Development center, Bharathiar University, Coimbatore, India.
    Research and Development center, Bharathiar University, Coimbatore, India.
    Research and Development center, Bharathiar University, Coimbatore, India.
    Research and Development center, Bharathiar University, Coimbatore, India.
    Department of Radiation Oncology, Yashoda Hospitals,Secunderabad,India.

    شاپا
    1513-7368
    2476-762X
    URI
    https://dx.doi.org/10.22034/APJCP.2017.18.12.3439
    http://journal.waocp.org/article_53789.html
    https://iranjournals.nlai.ir/handle/123456789/36243

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب