نمایش مختصر رکورد

dc.contributor.authormovahed pour, Raminen_US
dc.contributor.authorKord Jamshidi, Mariaen_US
dc.contributor.authorMahdavinejad, Mohammadjavaden_US
dc.date.accessioned1399-07-09T08:30:01Zfa_IR
dc.date.accessioned2020-09-30T08:30:01Z
dc.date.available1399-07-09T08:30:01Zfa_IR
dc.date.available2020-09-30T08:30:01Z
dc.date.issued2017-09-01en_US
dc.date.issued1396-06-10fa_IR
dc.date.submitted2015-12-30en_US
dc.date.submitted1394-10-09fa_IR
dc.identifier.citationmovahed pour, Ramin, Kord Jamshidi, Maria, Mahdavinejad, Mohammadjavad. (2017). An Efficient Double Skin Façade for an Office Building in Shiraz City. International Journal of Architecture and Urban Development, 7(3), 39-46.en_US
dc.identifier.issn2228-7396
dc.identifier.issn2345-2331
dc.identifier.urihttp://ijaud.srbiau.ac.ir/article_11522.html
dc.identifier.urihttps://iranjournals.nlai.ir/handle/123456789/342629
dc.description.abstractEnergy efficiency in office buildings has been the center of attention for many researches. This special attention is due to highly energy consumption in this building type. Refinement of facade and building's envelop is a good approach to reduce buildings energy requirements. Double skin facade concepts are commonly used to achieve that object. Although the concept is not new, there is a growing tendency from the architects to put it into practice. However inappropriate selection of technical parameters in this kind of façade, such as its interior/ exterior openings, layers, materials and shading device would lead to reverse expected results. The objective of this study is to improve and optimize the thermal performance of an office building in hot and dry climate. For this purpose a suitable double skin façade concept is designed to reduce the building's annual energy requirements. This concept is optimized by integrating with a windcatcher. The optimization is performed based on simulating a designed office building by Energy Plus software. The results revealed that double skin façade integrated with wind catcher can significantly reduce annual energy requirement by 26.65%. The proposed solution can be considered as an effective platform for sustainable architecture and reduction of energy consumption.en_US
dc.format.extent1076
dc.format.mimetypeapplication/pdf
dc.languageEnglish
dc.language.isoen_US
dc.publisherScience and Research Branch, Islamic Azad Universityen_US
dc.relation.ispartofInternational Journal of Architecture and Urban Developmenten_US
dc.subjectDouble skin façadeen_US
dc.subjectWindcatcheren_US
dc.subjectOptimal designen_US
dc.subjectOffice buildingsen_US
dc.titleAn Efficient Double Skin Façade for an Office Building in Shiraz Cityen_US
dc.typeTexten_US
dc.typeOriginal Paperen_US
dc.contributor.departmentM.A., Yasuj Branch, Islamic Azad University.en_US
dc.contributor.departmentAssidtant Professor, Faculty of Art and Architecture, University of Mazandaran, Babolsar, Iran.en_US
dc.contributor.departmentAssociate Professor, Department of Architecture, Faculty of Art and Architecture, Tarbiat Modares University, Tehran, Iran.en_US
dc.citation.volume7
dc.citation.issue3
dc.citation.spage39
dc.citation.epage46
nlai.contributor.orcid0000-0002-6454-6518


فایل‌های این مورد

Thumbnail

این مورد در مجموعه‌های زیر وجود دارد:

نمایش مختصر رکورد