• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Basic Medical Sciences
    • Volume 12, Issue 1
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • Iranian Journal of Basic Medical Sciences
    • Volume 12, Issue 1
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Development and Validation of a HPLC Method for Determination of Pefloxacin in Tablet and Human Plasma

    (ندگان)پدیدآور
    Gauhar, ShahnazAli, Syed AyubShoaib, HarrisShyum Naqvi, Syed BaqirMuhammad, Iyad Naeem
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    138.7کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Objective(s) Developing and validating a simple, efficient, reproducible and economic reversed phase high performance liquid chromatographic (RP-HPLC) method for the quantitative determination of pefloxacin in bulk material, tablets and in human plasma. Materials and Methods A shim-pack CLC-ODS column and a mobile phase constituting acetonitrile: 0.025 M phosphoric acid solution (13:87 v/v, pH 2.9 adjusted with KOH) were used. The flow rate was 1 ml/min and the analyses performed using ultraviolet (UV) detector at a wavelength of 275 nm using acetaminophen as an internal standard. Results The developed method showed good resolution between pefloxacin and acetaminophen. It was selective to pefloxacin and able to resolve the drug peak from internal standard and from formulation excipients. The percentage of coefficient variation (CV) of the retention times and peak areas of pefloxacin from the six consecutive injections were 0.566% and 0.989%, respectively. The results showed that the peak area responses are linear within the concentration range of 0.125 qg/ml-12 qg/ml (R2= 0.9987). The limits of detection (LOD) and limits of quantitation (LOQ) for pefloxacin were 0.03125 qg/ml and 0.125 qg/ml. The intra-day and inter-day variation, RSD were 0.376-0.9056 and 0.739-0.853 respectively; also, inter-day variation with relative standard deviation (RSD) were 0.1465-0.821 in plasma. The accuracy results of 70%, 100%, and 130% drugs were 100.72%, 100.34%, and 100.09%, respectively. Conclusion The method is linear, quantitative, reproducible and could be used as a more convenient, efficient and economical method for the trace analysis of drug in biological fluids, in raw material and tablets.
    کلید واژگان
    Antibiotics
    fluoroquinolone
    High Performance Liquid Chromatography
    Pefloxacin
    Quantitative analysis
    Validation studies

    شماره نشریه
    1
    تاریخ نشر
    2009-01-01
    1387-10-12
    ناشر
    Mashhad University of Medical Sciences
    سازمان پدید آورنده
    Department of Pharmaceutics, Faculty of Pharmacy, University of Karachi, Karachi, Pakistan
    Department of Pharmaceutics, Faculty of Pharmacy, University of Karachi, Karachi, Pakistan
    Department of Pharmaceutics, Faculty of Pharmacy, University of Karachi, Karachi, Pakistan
    Department of Pharmaceutics, Faculty of Pharmacy, University of Karachi, Karachi, Pakistan
    Department of Pharmaceutics, Faculty of Pharmacy, University of Karachi, Karachi, Pakistan

    شاپا
    2008-3866
    2008-3874
    URI
    https://dx.doi.org/10.22038/ijbms.2009.5133
    http://ijbms.mums.ac.ir/article_5133.html
    https://iranjournals.nlai.ir/handle/123456789/339619

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب