• ثبت نام
    • ورود به سامانه
    مشاهده مورد 
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 33, Issue 9
    • مشاهده مورد
    •   صفحهٔ اصلی
    • نشریات انگلیسی
    • International Journal of Engineering
    • Volume 33, Issue 9
    • مشاهده مورد
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Determination of Riboflavin by Nanocomposite Modified Carbon Paste Electrode in Biological Fluids Using Fast Fourier Transform Square Wave Voltammetry

    (ندگان)پدیدآور
    Asgharian Marzabad, M.Jafari, B.Norouzi, P.
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    634.5کیلوبایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    Herein, fast Fourier transformation square-wave voltammetry (FFT-SWV) as a novel electrochemical determination technique was used to investigate the electrochemical behavior and determination of Riboflavin at the surface of a nanocomposite modified carbon paste electrode. The carbon paste electrode was modified by nanocomposite containing Samarium oxide (Sm2O3)/reduced graphene oxide (RGO) (2:1) to improve detection sensitivity of Riboflavin under optimal experimental conditions. Furthermore, the signal-to-noise ratio was significantly increased by application of discrete fast Fourier transformation analysis, background subtraction and two-dimensional integration of the electrode response over the selected potential range and the time window. Obtained cyclic voltammograms demonstrated a diffusion-controlled reversible electron transfer reaction for Riboflavin in phosphate buffer solution (pH=7.2). The peak potential values were pH-dependent, involving the same numbers of protons and electrons. To obtain the maximum sensitivity, some effective parameters such as scan rate (10 mV/s), accumulation time (0.2 s) and potential (+400 mV), frequency (1420 Hz) and amplitude (20 mV) were optimized. As a result, determination of Riboflavin using FFT-SWV showed a linear range of response from 10 to 400 nM (R2=0.9993), with limit of detection of 0.86 nM. An acceptable recovery percent was also obtained for Riboflavin in human plasma samples as criteria of measurement applicability of the proposed modified electrode.
    کلید واژگان
    fast Fourier transforms square wave voltammetry
    Riboflavin
    Reduced graphene Oxide
    Samarium Oxide

    شماره نشریه
    9
    تاریخ نشر
    2020-09-01
    1399-06-11
    ناشر
    Materials and Energy Research Center
    سازمان پدید آورنده
    CEITEC—Central European Institute of Technology and Department of Chemistry, Faculty of Science, Masaryk University, Kamenice 5, Czechia
    Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, Iran
    Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran, Iran+Biosensor Research Center, Endocrinology & Metabolism Molecular-Cellular Sciences Institute, Tehran University of Medical Sciences, Tehran, Iran

    شاپا
    1025-2495
    1735-9244
    URI
    https://dx.doi.org/10.5829/ije.2020.33.09c.01
    http://www.ije.ir/article_108476.html
    https://iranjournals.nlai.ir/handle/123456789/337854

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب