    Effect of Initial Local Failure Type on Steel Braced Frame Buildings against Progressive Collapse

    (ندگان)پدیدآور
    Pordel Maragheh, BabakJalali, AbdolrahimMirhoseini Hezaveh, Seyyd Mohammad
    Thumbnail
    دریافت مدرک مشاهده
    FullText
    اندازه فایل: 
    1.310 مگابایت
    نوع فايل (MIME): 
    PDF
    نوع مدرک
    Text
    Original Article
    زبان مدرک
    English
    نمایش کامل رکورد
    چکیده
    In many studies, the alternative load path method (APM) has been used for progressive collapse analysis. In this method, one or several columns of the building are removed and the building response is investigated. This method ignores the initial local failure cause of building and this can affect the structural response. Investigation of ignoring the initial local failure cause of steel braced frames is the main purpose of this research. The variables include the type of progressive collapse investigation (ignoring the initial cause of failure or APM, considering blast loading and the heat caused by the fire as the initial causes of failure) and the location of the initial local failure in plan (outer and inner frame) and in floors (1st, 2nd and 3rd). 4-story braced steel buildings were simulated using ABAQUS software and the responses were compared using different methods. The most important results showed that the axial forces are very noticeable in the columns around the damaged site if the initial local failure caused by explosive loading; while these forces are ignored when APM is used. Therefore, due to this significant difference, if the design of a steel building is to be considered against progressive collapse, it is recommended to consider the initial local failure in order to make the appropriate design in accordance with it. Therefore, the initial loading type has a very significant effect on the structure response, and ignoring the initial local failure can lead to incorrect predictions of the structure response.
    کلید واژگان
    Progressive collapse
    Finite element method
    Alternate load path method
    Braced Steel Buildings
    Blast
    Fire

    شماره نشریه
    1
    تاریخ نشر
    2020-01-01
    1398-10-11
    ناشر
    Materials and Energy Research Center
    سازمان پدید آورنده
    Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran
    Faculty of Civil Engineering, University of Tabriz, Tabriz, Iran
    Department of Civil Engineering, Arak Branch, Islamic Azad University, Arak, Iran

    شاپا
    1025-2495
    1735-9244
    URI
    https://dx.doi.org/10.5829/ije.2020.33.01a.05
    http://www.ije.ir/article_101145.html
    https://iranjournals.nlai.ir/handle/123456789/335626

    مرور

    همه جای سامانهپایگاه‌ها و مجموعه‌ها بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌هااین مجموعه بر اساس تاریخ انتشارپدیدآورانعناوینموضوع‌‌ها

    حساب من

    ورود به سامانهثبت نام

    آمار

    مشاهده آمار استفاده

    تازه ترین ها

    تازه ترین مدارک
    © کليه حقوق اين سامانه برای سازمان اسناد و کتابخانه ملی ایران محفوظ است
    تماس با ما | ارسال بازخورد
    قدرت یافته توسطسیناوب